Instruction Manual of 

Reverse Osmosis Unit 

Excel

 

 

Equipment 

This reverse osmosis unit consists of: 

 

water tap connector ¾"i - 6i, PE pressure tube black 6a -
 4i, 10" filter housing with combifilter cartridge (activated 
carbon and sediment filter 5 µm), reverse osmosis 
membrane housing with plastic membrane: polyamide / 
polysulfone (TFC), flushing valve, pressure gauge, and 
each four screws and plugs for mounting the unit at the 
wall. 

Principe of function 

The water pressure pushes the tap water through a semi 
permeable membrane. The membrane is extremely fine, so 
soluble substances like salts (hardness, nitrate, silica) and 
organic substances like pesticides and medicaments are 
rejected. To prevent blocking of the membrane a part of 
the water with the concentrated wastes has to drained with 
the brine (concentrate). 
The quality and water flow of the pure water (permeate) of 
a reverse osmosis unit is controlled by some factors. The 
better the tap water (feed water) the better the permeate; 
but in most cases it is impossible to change the tap water 
quality. - The higher the water pressure the higher the pure 
water flow and the better the pure water quality. Therefore 
it is not possible to use a reverse osmosis unit below 3 bar 
water pressure (see pressure gauge 17). To higher the 
pressure it is possible to use a booster pump. - The higher 
the water pressure the higher the water flow. But don't use 
a reverse osmosis unit above 30°C (90°F); the membrane 
would be violated.  
All AquaCare reverse osmosis units are build with a 
sediment filter to prevent the membrane of particles and 
with an activated carbon filter to prevent the membrane of 
chlorine and other oxidants. The type 

Excel

 combines both 

filters in one combifilter.  
The flushing valve (20) performs the regular maintenance. 
If you open the valve the water flows with high speed 
along the membrane and cleans it. The life time of the 
membrane increases enormously. 

Mounting the unit 

The best place of an AquaCare reverse osmosis unit is in 
the near of a water tap or in the near of the aquarium. 
Please note that you have to have enough place to be able 
to maintain the unit. The best place is cool and free of 
sunlight.  
If the unit has to be mounted more than 5 metres away 
from the water tap, you must use 10 mm pressure tube 
instead of 6 mm tube for the feed water. If the waste water 
connector is more than 5 metres away form the reverse 
osmosis unit, please use 10 mm tube for the brine, too. 
The mounting board (6) which contains the reverse 
osmosis unit can be mounted at a wall - screws and plugs 
are delivered. Please mark the wholes of the mounting 
board at the wall. Then drill two or four holes (6 mm 
diameter in stone) minimum 30 mm deep. Push the plugs 
into the holes and use the screws to fix the board at the 
wall. If you want to fix it on wood or plastic drill holes 
with diameters between 2.5 and 3.0 mm. 

Then connect the tubes (look at Fig. I). All tubes (5) has to 
be cut with a sharp knife (straightly cut ends!). Please use 
only the original AquaCare pressure tubes. Otherwise 
leakage is possible. 
The pressure tube is pushed into the push fit fitting until it 
cannot be pushed further. The tube should be gently pulled 
to ensure that the connection is sound. The connection can 
be released by pushing back the collet and pulling the tube 
out. 
The water tap connector (4) must be screwed onto a tap - 
do not forget the seal (1). If there is no 3/4" male available 
please ask AquaCare. Please do not use any tools to 
prevent destruction. Push the black tube into the fitting (3) 
and cut it in the right length to connect the unit. The other 
end of the tube must be pushed into the feed water inlet 
(8). 
All in- and outlets of the membrane housing are plugged 
with tube plugs. Disassemble the red plugs. Now push the 
tube at the right side of the 10" filter housing (9) in the 
downwards fitting of the membrane housing (15). The rest 
of the tube can be used for connecting the pure water (B) 
and brine outlet (C). Push the tube into the pure water 
outlet and cut the tube at the right length. 
The brine outlet has to be connected to a drain. Special 
drain saddles are available at AquaCare. 
Please collect the plugs for further applications. 

Attention:

  

The feed water should be below 30°C (90°F). Otherwise 
the membrane would be destroyed.  
Pure water (permeate) and brine (concentrate) have to be 
flow without resistance. The tubes should not be sharp 
bended. No needle or shut of valves should not be used. If 
you want to use an magnetic valve to shut off the reverse 
osmosis unit automatically, please build it between 10" 
combifilter and membrane housing. 

Putting into operation 

Open the water tap - the air escapes from the unit. Then 
close the flushing valve.  

Attention: the flushing valve do not shut totally! Do not 
close it tightly! Otherwise the correct function of the 
reverse osmosis unit is not guaranteed. 

Please search for leakage (look at “faults”). 
Now open the flushing valve (20) and flush the unit the 
first time for 30 min. The water should be flow in a fast 
way. - Close the flushing valve. The first 2 liters pure 
water have to be spilled. After 2-3 hours operation check 
water quality and water flow of the unit (look at 
“maintenance”). 

Maintenance 

To guarantee good and long function of the reverse 
osmosis unit, it has to be carefully maintained. 

Maintenance with every use - the flushing 

valve 

Flush the unit before and after use for c. 2 min (if you 
have very hard feed water flush for 5 min). If the unit 
works without any stop flush every week for minimum 
10 minutes (hard water 20 min). 

To flush the membrane 

Summary of Contents for Excel 1000 1:1

Page 1: ...e water outlet C Abwasserausgang Waste water outlet 1 Flachdichtung Seal 2 Muffe i i Muffle i i 3 Fitting a 6i Fitting a 6i 4 Wasserhahnanschluss Tap water connector 5 6 mm PE Schlauch 6 mm PE tube 6...

Page 2: ...hadstoffen angereicherte Teil des Wassers vor der Membran abgeleitet werden Abwasser Konzen trat Die Reinwasserqualit t und leistung einer Umkehr osmoseanlage wird von mehreren Faktoren beeinflusst Je...

Page 3: ...n den Deckel wieder auf das Geh use ffnen Sie den Wasserhahn Rohwasser die Luft ent weicht aus der Anlage Nachdem ein gleichm iges Rau schen zu h ren ist schlie en sie das Sp lventil 20 Ach tung Venti...

Page 4: ...Zeile mit dem Leitwert H rte der Ihrem Leitungswasser am besten entspricht Wenn z B Ihr Leitungswasser einen Leitwert von 550 S cm hat gehen Sie in die Zeile 500 S cm Das Reinwasser darf dann h chste...

Page 5: ...mit Vaseline ein Sollten die O Ringe Risse oder Macken aufweisen m ssen sie ersetzt werden berpr fen Sie ob in der Geh useaufnahme des Membran sammelrohrs ein Riss ist Wenn ja muss das Membrange h us...

Page 6: ...stone minimum 30 mm deep Push the plugs into the holes and use the screws to fix the board at the wall If you want to fix it on wood or plastic drill holes with diameters between 2 5 and 3 0 mm Then c...

Page 7: ...uring is the determination of the electrical conductivity You can also determine the water hardness by quick test Please use the instruction manuals of these test If you have determined the conductivi...

Page 8: ...tes and close it If the brine do not run please change the flushing valve Too much pure water and to low rejection Check the seals at the pure water collector at the membrane If they are not in order...

Page 9: ...R 087x3 5N Membranen membranes Excel 600 300 GPD 190 075 Modulgeh use 2812 membrane housing 2812 191 106 Halter clip 191 102 Halter clip 191 107 PE Schl uche PE tubes PE06 4rt PE06 4bl PE06 4sw Flachd...

Page 10: ...Membrantyp Type of Membran Wickelmodul spiral wound Membranmaterial Material of membrane Polyamid TFC Membrangr e Excel 90 Excel 160 Excel 180 1 1 Excel 320 Excel 360 1 1 Excel 480 Excel 1000 1 1 Memb...

Reviews: