–SERVICE and MAINTENANCE
CONTROL BOX
There are little serviceable parts on the
Pool Pilot
®
Soft Touch
Control Box except the fuses. For any other problems with the
Control Box, please contact the Factory or Authorized Dealer/Service Center.
To remove the Control Box Cover and access the fuses, follow these steps.
POOL PILOT
Soft Touch
Control Circuit Board
F3
F2
Front of Unit
Wire Harness Connection
Inner Metal
Top Cover
Inside Top Cover
Cover
F1
Loosen (4) knobs
Lift off cover and disconnect
Remove (3) screws and
Access is gained to
(you do not need to)
wire harness (Control Circuit
lift off metal cover.
electrical connections,
(remove these).
board removes with cover).
The (4) Mounting holes, at
fuses, and pump/aux
each corner are accessed here
relay.
(without removing metal cover).
Fuse Location and Ratings
F1
Main AC Power Fuse
3 Amps 250 VAC (230 Volts)
6 Amps 250 VAC (115 Volts)
F2
Control Panel Circuit Board Fuse
3 Amps 250 VAC
F3
Cell Fuse
20 Amps 250 VAC
TRI-SENSOR ASSEMBLY
The Tri-sensor assembly tests for Flow, Salt and Water temperatures. A minimum flow rate of 15 gpm (3.4 m³/hr) is required
to activate the flow switch. As the water flow closes the paddle, a magnet activates a micro switch to verify proper flow. The
Salt sensor protects against low salt levels and the temperature sensor protects against cold water temperatures. Both of which
can contribute to accelerated cell failure.
►
Note:
The use of high strength magnet devices in the close proximity
of the
T
ri-sensor can cause the flow switch to read incorrectly.
Remove the Tri-
s
ensor as follows (with pump off):
Remove both screws from the sides of the Tee Assembly.
With the aid of large Channel-lok® (or similar) pliers, firmly
grip the Tri-
s
ensor assembly and move back and forth while
removing the Tri-
s
ensor from the tee.
Inspect the thin metalic paddle for erosion and straightness.
Take care not to twist or tweak this paddle, which can cause
inaccurate flow readings.
Inspect the salt sensor blades for scale and debris and clean
if necessary. See page 13 for cleaning instructions. Follow
the directions for Manual Cell Cleaning.
Check the
T
ri-sensor assembly for any damage to the plastic
housing and replace if needed.
directional
arrow
screws
one on each side
WARNING: Failure to heed the following may result in permanent injury or death.
ELECTRICAL SHOCK HAZARD – Turn off the electrical power
to the unit,
from ciruit breaker,
before servicing.