Installation Steps:
Details on each step of the installation process are presented on the following pages:
1. Plumbing the Manifold Assembly (see below)
2. Mounting the Control Unit (page-21)
3. Electrical Requirements & Connections (pages 21-22-23)
a. Grounding and bonding
b. Line (high) voltage wiring (Pool Pilot Digital to an external timer or controller)
c. Low voltage wiring
•
SuperCell cable
•
Tri-sensor cable
4. Preparing the Water (pages-24 & 25)
5. Programming and Setup for Site Parameters. (pages 26-32)
Note: Insure flow rates for two-speed pump can provide sufficient flow at low speed.
Plumbing the Manifold Assembly:
STEP-1: Select the location for installing the manifold:
It is recommended the manifold be installed prior to installation of the Control Unit. The Control Unit
must be installed close enough to the Manifold Assembly to allow the Tri-Sensor and SuperCell cables
sufficient slack to enable component service and maintenance. The cables are 12’ long.
If using the Bypass Manifold/Cell (# 94105), the assembly must be installed in a vertical orientation as
illustrated in the diagram on previous page. This orientation prevents hazardous gas buildup in the system,
should the flow switch should fail to detect insufficient flow. WARNING! Place manifold vertical ONLY.
The direction of the water flow through the manifold must be as indicated for the system to operate properly.
For a Pool/Spa combination, the manifold must be located as the last component in the POOL RETURN
LINE (to avoid over-sanitization of the spa).
Flow Rates Within Normal Range:
The manifold can be directly plumbed into the system (as shown in the diagrams on the prior page).
If the flow rate for the system is less than 20-gpm (76 L/m), a larger pump must be installed (or steps
taken to improve flow rate).
Plumbing Requirements:
The Manifold Assembly is 2" Schedule 40 PVC, and is typically plumbed into the pool return line; and, if
applicable, after the heater and spa return diverter valve.
INSTALLATION
(CONTINUED)
Flow Rates Exceeding 100-gpm (379 L/m)
T
O
P
OOL
R
ETURN
F
ROM
P
UMP
&
F
ILTER
# 75082
5-
LB
SPRING
BYPASS
CHECK
VALVE
MUST
BE
PLUMBED
IN
PARALLEL
WITH
THE
MANIFOLD
.
F
ROM
P
UMP
&
F
ILTER
T
O
P
OOL
R
ETURN
# 94105
WARNING!
MANIFOLD
VERTICAL
ONLY