Page - 18
Electrical Standards
Standards
Title
NFPA 70, Nat'l Elec.
Code 2017
The electrical installation must conform to the current
version of the National Electric Code (NEC), and all
applicable local and state codes
IEC 60335-1
Household and similar electrical appliances - Safety -
General Requirements
IEC 60335-2
Household and similar electrical appliances - Safety –
Particular requirements for electrical heat pumps, air-
conditioners, and dehumidifiers
UL 1995 & CSA C22.2
No. 236-15
Standard for Safety - Heating and cooling equipment
Table 2 - Standards
Grounding and Bonding
Follow local code requirements for proper grounding and bonding of heat pump equipment.
l
A bonding lug has been provided on the lower right-hand corner of the front access panel.
Surge Suppression
The use of approved commercial surge protectors is strongly recommended.
Sizing the Electrical Service
Refer to equipment data plate for specific information required to size electrical service and over-current
protection of the heat pump. Sizing is based on data plate information, wire size, wiring devices, and over-
current protection per applicable local codes and standards. See "
Identifying Model Specifications
Minimum and Maximum Operating Voltage
The heat pump must operate within specified voltages.
NOTICE
Failure to heed the following may result in damage to equipment.
l
Operating equipment under higher or lower voltage conditions may result in damage to your compressor, motors
or other electrical components. This damage will not be covered by the product warranty.
1. Measure site voltage. The site voltage
MUST
be measured under “FULL LOAD” conditions. Activate all
equipment using the same electrical panel as the heat pump.
2. If measured site voltage is outside listed ranges, immediately deactivate equipment until site conditions have been
corrected. If unsure of heat pump equipment rating, please
Identifying Model Specifications
Equipment Rating
Minimum
Site Voltage
Maximum
Site Voltage
A Voltage
(208 to 230 Volts)
Single Phase 60 hertz
200 Volts
253 Volts
B Voltage
(208 to 230 Volts)
Three Phase 60 hertz
200 Volts
253 Volts
1
-
Ins
ta
lla
tion
Summary of Contents for Leisure Temp LT1000
Page 2: ......
Page 9: ...Page 6 1 3 Dimensions Leisure Temp LT55 Leisure Temp LT400 1 Installation...
Page 10: ...Page 7 Leisure Temp LT600 Leisure Temp LT700 LT800 1 Installation...
Page 26: ...Page 23 Configure Call Flex Enter Installer Menus then proceed 1 Installation...
Page 30: ...Page 27 1 Installation...
Page 33: ...Page 30 1 Installation...
Page 36: ...Page 33 Configure for 24 Hour Mode Enter Installer Menus then proceed 1 Installation...
Page 37: ...Page 34 Configure for Scheduled Mode Enter Installer Menus then proceed 1 Installation...
Page 38: ...Page 35 1 Installation...
Page 41: ...Page 38 1 Installation...
Page 43: ...Page 40 1 Installation...
Page 46: ...Page 43 1 Installation...
Page 50: ...Page 47 1 Installation...
Page 53: ...Page 50 1 Installation...
Page 55: ...Page 52 1 Installation...
Page 72: ......