1.5.a Service Level Factory Defaults
Certain programming options have been preset at the factory. These options can be overwritten for certain site-
specific conditions.
Code
Description
Default
Value
Range
CFO
Call-Flex
Options
0
Set to off at the factory.
dbP
Pool Dead-
Band
Differential
1°
Set at factory. Do not adjust.
db5
Spa Dead-
Band
Differential
1°
Set at factory. Do not adjust.
DEL
Compressor
Time Delay
1 (4 minutes) Set to on (at 4 minutes) at the factory. Do not adjust.
dSC
Defrost
Sensor
Factory
Calibrated
Set at factory. Do not adjust.
dFd
Defrost
Delay
Factory
Calibrated
Set at factory. Do not adjust.
FS2
Flow
Switch /
Automatic
Thermostat
Switching
Option
0
0 = "No Switch"
1 = "Enable Switch"
JAO
External
Controller
0
0 = "No Controller"
2 = "Two Wire Controller"
3 = "Three Wire Controller"
LOC
Service
Level Entry
Point
50
00 - 99
tSC
Water
Sensor
Factory
Calibrated
Set at factory. Do not adjust.
Table 3 - Default Program Parameters Chart