Page - 13
Electrical Standards
Standards
Title
NFPA 70
The electrical installation must conform to the current
version of the NEC, and all applicable local and state
codes
NFPA 70 Article 440
Standard for Safety for Electric Spas, Equipment
Assemblies, and Associated Equipment
NFPA 70 Article 680
Standard for Safety for Swimming Pool Pumps, Filters,
and Chlorinators
IEC 60335-1-2001
Household and similar electrical appliances - Safety -
General Requirements
IEC 60335-2-40 2006
Household and similar electrical appliances - Safety –
Particular requirements for electrical heat pumps, air-
conditioners, and dehumidifiers
UL1995 & CSA C22.2
236-05
Heating and cooling equipment
Table 2 - Standards
Grounding and Bonding
Follow local code requirements for properly grounding and bonding heat pump equipment.
l
A bonding lug has been provided on the lower right hand corner of the front access panel.
Surge Suppression
The use of approved commercial surge protectors is strongly recommended.
Sizing the Electrical Service
Refer to equipment data plate for specific information required to size electrical service and over-current
protection of heat pump. Sizing is based on data plate information, wire size, wiring devices, and over-current
protection per applicable local codes and standards. See "Identifying Model Specifications" on page 26.
Summary of Contents for Heatwave Superquiet TropiCal