Aqua ZL 10.5 Manual Download Page 9

AQUA                                                                                                                                                                  Sauna Heater 

    E002B-23-10-12                                                                                                                                                                                            9       

(1)

 

Temp sensor frame (Fig 6) 

 

(Fig6) 

(2)

 

Temp sensor instruction (chart 6) 

Chart 7 

No. 

Parts 

Description   

Circuit board 

Circuit board 

Bracket 

Bracket 

Cover 

Protects the electronics 

Heat resistance 

Detects temperature 

High Temp cut of switch 

When temperature in sauna room exceed 120 

o

C or 248 

o

 

Chapter Three: Installation 

1.  Important 

Prior to installing sauna heater, please refer to Installation handbook and check it as following points: 

 

  Is  the  output  power  and  type  of  the  heater  suitable  for  the  Sauna  Room?  See  parameter  table  1. 

(Technical parameter). 

 

  Is the supply voltage suitable for the rated voltage of

 

sauna heater.   

 

  The location of the heater fulfils the minimum requirements concerning the distances given in Fig 7

 

and chart 8

 .and allow for safety and convenience.   

 

  Choose  the  cable  wire  according  to  table  1,  note  for  the  cable  to  the  heater  you  will  need  high 

temperature resistant sillicon rubber cable wire. 

 

  Do not install more than one heater in a sauna room unless twin-heater installations. (Warning: there 

must be 400 mm between two heaters when install two). 

Summary of Contents for ZL 10.5

Page 1: ......

Page 2: ...e installed by competent person This equipment must be connected to an all pole isolator of the correct rating Disconnect the power supply before exposing electrical connections The sauna heater shoul...

Page 3: ...inal2 5 1 5 40 50 ZL10 5 0CS105B 10 5 3 1 5 H1 H3 H5 3 2 0 H2 H4 H6 9 15 400 3N Terminal1 5 1 5 Terminal2 5 1 5 40 50 ZL12 0CS120B 12 0 6 2 0 H1 H6 10 18 400 3N Terminal1 5 2 5 Terminal2 5 2 5 40 50 Z...

Page 4: ...erature Size mm Model L W H OC S 0 110 32 230 120 248 76 42 27 4 Circuit Diagram for sauna heater and control Box i Sauna heater circuit diagram Fig 1 HEATING ELEMENT OCS090B 0CS170B Fig 1 a HEATING E...

Page 5: ...ax Output Power 12kw Max Output Power 12kw Light Ter m i nal 2 W W V V U U N N L N F N L3 L2 L1 N Ter m i nal 1 Ter m i nal 2 L3 L3 L2 L2 L1 L1 N N 1 2 3 RT 4 HI TEMP CUT OFF MANUAL RESET DOOR RED Pow...

Page 6: ...No parts description 1 Heat element heating 2 Shell Insulate the inner shell to prevent from scalding 3 Cover Panel Cover the electrical parts 4 terminal Connect the power supply 5 Power entry The rou...

Page 7: ...be on 12 Wait LED When this LED is on the count down timer is on 13 Sauna room Door interlock indicator LED When this LED is on the door has been opened since your count down timer has been set and so...

Page 8: ...ten wires 2 terminal Connect to the power supply 3 Terminal Connect to heater 4 Heater light and fan output Outlet of wires to heater light and fan and fasten wires 5 Control cable entry The entry of...

Page 9: ...it as following points Is the output power and type of the heater suitable for the Sauna Room See parameter table 1 Technical parameter Is the supply voltage suitable for the rated voltage of sauna h...

Page 10: ...ical connection can cause fire or electric shock Refer to fig 1a or fig 1b Electrical connection chart and fig 2 Fig 7 Chart 8 Safety distance Safety distance A min A max B min C min D min E max Model...

Page 11: ...talled at a height of approximately 1200mm for ease of use Installation method drill a 40mm hole on wall for the wires You can mount the panel by either drilling two holes 118mm apart for the screws o...

Page 12: ...1 5 Sauna heater Control box controller light fan and temperature sensor connection drawing Fig10A Fig 10B Fig 10C 6 Door interlock install the switch following the manufacturers instructions and conn...

Page 13: ...he heater Do not use ordinary stones which may emit harmful substances easily break and do not possess good heating capacity Wash the stones to clear the dust before putting them into the heater Stone...

Page 14: ...vent should be installed The inlet vent may be installed on the wall below the heater fig 15a when using mechanical ventilation inlet vent is placed 50cm above the heater fig 15b or on the ceiling ab...

Page 15: ...first use the elements and stones may smoke slightly and give off a smell please ensure the sauna cabin is well ventilated Connect to power supply press key temp and time windows will display data LED...

Page 16: ...e desired setting is reached press the window will stop flashing You can adjust from the time from 10 minutes to 8 hours Note the controller has a memory function if the power supply is not cut off th...

Page 17: ...fore the timer setting can be made once the timer begins if the door is opened it will cancel the countdown and won t operate until reset Chapter Five Trouble shooting Guide Please Note that we recomm...

Page 18: ...t circuit in the temperature sensor or the temperature is higher than 115 or 239 check the connection cable or change sensor 3 Change controller Chapter Six Maintenance We recommend that you inspect t...

Page 19: ...AQUA Sauna Heater E002B 23 10 12 19 For warranty claims and after sales service please contact your local dealer...

Reviews: