HC997-999
– MOD. D
TECHNICAL FEATURES
Digital multifunction solenoid metering pump
ENGLISH
ADSP9000033
03/09/2015 Rev.1.2
30/100
2.5 I
NTERNAL TERMINAL BLOCK
CAUTION: Always disconnect power when servicing the unit.
INPUT
PINS
DESCRIPTION
WHAT CONNECT
INPUT mA
1-2
Input to connect a 0÷20mA
current signal that comes from a
controller.
INPUT FLOW
3-4-5
Input to connect a flow sensor.
INPUT PULSE
6-7
Input to connect a water meter.
INPUT LEVEL
8-9
Input to connect a level probe.
INPUT
CHLORINE
JUMO
16-17
Input to connect
a chlorine A- J probe.
3.0 USER MENU
Once the pumps is switched on the display show an user menu and is possible to read some information regarding
the functioning mode and the possibility to pause and prime the pump.
Moreover from the standby menu is possible to enter in the user menu to perform some functions.
3.1 P
AUSE THE PUMP
From the standby menu press the key, the display will show:
Press twice the key to go back at the standby menu.
3.2 P
RIMING THE PUMP
From the standby menu press twice the key, the display will show:
Keep pressed the key to activate the pump.
Press the key to go back at the standby menu.
997 Break