HC997-999
– MOD. D
SETTINGS AND CALIBRATION
Digital multifunction solenoid metering pump
ENGLISH
ADSP9000033
03/09/2015 Rev.1.2
42/100
4.6.2
Settings menu
– Date and clock
This menu allow to set the date and clock..
Press the keys to set the desired values.
Press the key to move the cursor on the next field, the value to modify is blinking.
Press the key to go back at the previous menu or move the cursor at the
previous field.
4.6.3
Settings menu
– Calibration
This menu allows to set the flow rate in mL of the pump in
100 strokes.
To perform the calibration following this procedure:
8.
Priming the pump, the chemical has to go out from
the delivery.
9.
Positioning a graduate container (at least 250 mL)
on the suction of the pump.
10. Save the quantity of the chemical inside the
container (
L1
).
11. Enter in the calibration menu and activate the pump.
12. A countdown will start.
13. When the pump stops, save the remaining quantity
of chemical inside the container (
L2
).
14. Press the keys to set the mL drawn
that is the difference between
L1- L2
and then press the
key to confirm.
4.6.4
Settings menu
– Units of measurement
This menu allows to set the units of measurement of the
pump’s flow rate.
The units of measure L/h e mL/min are active only after the
calibration.
Press the keys to scroll the menu entries..
Press the key to select the desired entry.