HC150 / HC101
INSTALLATION
Solenoid driven dosing pump
ENGLISH
ADSP9500090
Rev. 3.1 del 05/10/2020
7
2.0 INSTALLATION AND TECHNICAL FEATURES
2.1 General regulations
Pump installation must be carried out as follows:
On a horizontal support (ex.: storage tank) or on the wall-mount bracket (optional) as long as the pumps
remains in a vertical po/- 15°.
Away from sources of heat in dry locations, at a maximum temperature of 45° C, and a minimum of 0° C.
In a ventilated environment and easily accessible to an operator for periodic maintenance.
Above the level of the liquid to be dosed, at a maximum height of 1.5 metres, nevertheless bearing in mind
that if the requirements of the system envision the need to position the pump below the level of the liquid
(positive suction head), in order to avoid problems with the siphon, always use the injection valve or a
counter pressure valve.
Do not install the pump above the tank when using liquids that emit fumes, unless it is sealed shut.
2.2 Accessories included
When you purchase the pump, it includes everything required for correct installation, specifically:
Suction filter (1 pc).
Injection valve (1 pc).
4 x 6 polyethylene delivery tube (2 m.).
PVC Crystal suction tube (2m.)
PVC Crystal tube to insert into the purge (2 m.).
Wall mounting bracket (1 pc).
Dowels and screws.
2.3 Electrical connections
2.3.1 Power supply
The pump is supplied, as standard, with a three-pole power cable, but without a plug. Connect the cable to a
suitable 230 Vac 50/60 Hz power supply, which can be with plug or with direct connection to the electrical panel
with a suitable disconnector
.
If it is necessary to replace the power cable, this must be done by specialized personnel. Open the pump by
removing the 4 screws located on the rear of the case (see fig. 1 chap. 8) and connect the cable, through the cable
gland, exactly like the existing cable, using cable H05VV-F 3x0.75 mm2. Close the pump after connection.
2.3.2 Low level probe
Connect the black- BNC connector to the corresponding connector located at the bottom of the pump.
The input for the low level probe has an hysteresis of 3 seconds when the alarm is either activated or
deactivated.
HC150
HC101
Level probe
Summary of Contents for HC101 1
Page 1: ...ADSP9500090 Rev 3 1 del 05 10 2020 1 PUMPS SERIES HC150 HC101 ...
Page 21: ...ADSP9500090 Rev 3 1 del 05 10 2020 21 ...
Page 22: ...ADSP9500090 Rev 3 1 del 05 10 2020 22 FIG 2A SERIE HC101 CON BASE BASE MOUNTING ...
Page 27: ...ADSP9500090 Rev 3 1 del 05 10 2020 27 Fig 6A HC101 Esploso Exploded view ...
Page 34: ...ADSP9500090 Rev 3 1 del 05 10 2020 34 PUMPS SERIES HC150 ...