HC150 / HC101
PROGRAMMING THE PUMPS
Solenoid driven dosing pump
ENGLISH
ADSP9500090
Rev. 3.1 del 05/10/2020
10
3 PROGRAMMING THE PUMPS
3.1 HC150 / HC101 costant
Programming the HC150 / HC101 costant pump or in constant mode is based on the setting, using the knob,
regulating the number of pulses per minute that the pump must carry out.
It is possible to regulate the number of pulses per minute, and therefore the flow of the pump, using two regulating
scales:
Full
: 0…100%
Reduced: 0…20%.
3.1.1 Scale change procedure
The following procedure allows you to switch from one scale to the other.
To perform this operation it is advisable to use a medium flat-tip screwdriver.
Turn the regulating knob to the minimum 0% (fully rotated counter clockwise):
The frequency of the flashing LED (green) indicates the scale that is currently in use:
quick flashing: 0…100%
slow flashing: 0…20%.
Turn the regulating knob to the maximum position (fully rotated clockwise) immediately followed by (within
2 seconds) bringing the timer back to the minimum position.
2 seconds
The frequency of the flashing LED has now been changed to indicate the change in regulating scale,
repeat again if necessary.
3.1.2 Meaning of two-colour LED
Colour of the
LED
Status of the
LED
Position of the
regulating knob
Operating status of the
pump
Green
Flashing
Different from 0%
ON
– injection with each
flash of the LED
Green
Flashing
0%
OFF
– Signals the scale
Quick flashing: 0…100%
Slow flashing: 0…20%.
Red
Steady
Different from 0%
OFF
– level alarm
Red
Flashing
Different from 0%
OFF
– temperature alarm
Summary of Contents for HC101 1
Page 1: ...ADSP9500090 Rev 3 1 del 05 10 2020 1 PUMPS SERIES HC150 HC101 ...
Page 21: ...ADSP9500090 Rev 3 1 del 05 10 2020 21 ...
Page 22: ...ADSP9500090 Rev 3 1 del 05 10 2020 22 FIG 2A SERIE HC101 CON BASE BASE MOUNTING ...
Page 27: ...ADSP9500090 Rev 3 1 del 05 10 2020 27 Fig 6A HC101 Esploso Exploded view ...
Page 34: ...ADSP9500090 Rev 3 1 del 05 10 2020 34 PUMPS SERIES HC150 ...