INSTALLATION SCHEME
Install the water softener in the arrival area and after the main counter.
Let a sufficient distance between your softener, walls or other equipment to facilitate the supply of
salt or for maintenance.
A water softener must be installed before the water heater or boiler.
WARNING: before proceeding with installation ensure to discontinue water
coming home at counter water
INSTALLING THE DRAIN OF REGENERATION
Fix the drain hose to the fitting located on the head of the softener (we
recommend using a hose clamp)
Cut the pipe length needed to get to the outlet of the discharge
Connect the exhaust pipe of regeneration to a drain (better if provided with siphon)
CAUTION: Through the drain pipe is ejected the water used during the
regeneration phase. The water is discharged under pressure. For this
reason it is recommended to properly secure and stable so the pipe to
prevent flooding in the place of installation of the water softener.