STANDARD CONSOLE
FUNCTIONING
Control console for
eco•wash
system
ENGLISH
ADSP7000604
rev. 1.3
17/09/2015
18/62
Return to stand-by mode > keep the
Enter
key pressed for about 3 seconds. (If no key is pressed for 2
minutes, automatically returns to stand-by status).
During the priming phase the pumps function for 60 seconds.
In the priming phase, when the pump is in alarm (ER close to the number of the pump) can not be
primed.
3.8
In diagnostic 1
This phases enables checking the status of the pumps and of the inputs of the signals module.
It is possible to access the diagnostic 1 mode during execution of a program
or if in stand-by, by pressing the
F
key. The display shows:
When a pump or signal is active, the corresponding number flashes. The
flashing of the letter W indicates the opening of the flushing kit solenoid valve.
In diagnostic 1 mode it is possible to perform the following operations:
Return to previous mode > briefly press the
F
key (if no key is pressed for 30 seconds, automatically
returns to previous mode).
3.9
In diagnostic 2
This phase enables checking the status of the communications between the various modules composing the
system.
It is possible to access diagnostic 2 mode during execution of a program or if in stand-by, by keeping the keys
F
and
Enter
simultaneously pressed for about 3 seconds. The display shows:
In diagnostic 2 mode it is possible to perform the following operations:
Check the various modules > press the
F
key
Return to previous mode > briefly press the
Enter
key (if no key is pressed for 30 seconds, automatically
returns to previous mode).
3.10 Display adjustment
In this menu it is possible to regulate the contrast and brightness of the display.
It is possible to access the display regulation mode only if in stand-by.
Keeping keys
/►
and
Enter
simultaneously pressed for about 3 seconds, the display shows:
When the console is in stand-by regulation mode, it is possible to perform the following operations:
Move the cursor between Contrasto (Contrast) and Luminosità (Brightness) > briefly press the
Enter
Increase and decrease percentage of the selected entry > press the
keys
Return to previous mode > keep the
Enter
key pressed for about 3 seconds (if no key is pressed for 30
seconds, automatically returns to previous mode).
P: 12345678910W
S: 12345678
Check
Modules
Contrast: 100%
Brightness: 100%