STRUCTURAL DATA AND TECHNICAL CHARACTERISTICS
The main indications concerning the equipment’s characteristics are given hereafter.
5.4
EQUIPMENT
’
S TECHNICAL CHARACTERISTICS
The dimensions, the bulks
,
the connection dimensions and the weights of the different filters are
reported on the component cards enclosed at the end of this handbook - picture 13.1
–
Filters should operate only with:
-
aqueduct or ground water
-
seawater;
-
water mixed with sodium hypochlorite in compliance with the UNI 901:2002 rule in a
solution of max 0,2 mg/l ( 2 ppm).
The equipment can be submitted to the working and burst pressure of:
ATTENTION:
Before the installation check that the inlet system, connected to
the filter, is provided with suitable devices which limit and prevent
the overflow of the maximum pressure inside the filtration system.
The fluid temperature used by the equipment should be included in the following range:
T
min
: +5°C
T
max
: +40°C
ATTENTION:
If it is provided that the fluid temperature can go below the
freezing point, isolate the equipment from the inlet system
connected to it and empty it, according to the conditions specified
in the maintenance section.
6
RISKS CONNECTED TO THE EQUIPMENT
6.1
UNIVERSALITY
For its own conformation, for its structural prerogatives and for the work that should be accomplish,
the equipment shows some not eliminable risks hereafter described.