Models 504 thru 2004

Category I with vertical vent

Models 503 thru 2003

Category IV Venting

Up to 

87%

thermal efficiency!

Summary of Contents for 2004

Page 1: ...Models 504 thru 2004 Category I with vertical vent Models 503 thru 2003 Category IV Venting Up to 87 thermal efficiency ...

Page 2: ...te which may form during initial start up or brief periods of cold water operation eliminating the need for a boiler condensate drain This saves you money on installation costs as well as the headache of dealing with multiple condensate drains True Modulation Modulation is nothing new to Raypak we have honed our gas modu lation experience for over 50 years The Raypak MVB will infinitely track the ...

Page 3: ...r applications that require reliable protection against harmful con densation caused by frequent extended cold water start ups Raypak s Cold Water Start pro tection system utilizes a proportional three way valve to bypass water from the boiler out let to the inlet during start up when the sys tem return water temperature is below the minimum acceptable level See Cat 1000 19 Cold Water Run For appl...

Page 4: ...0 84 1425 1211 85 1071ª 2004 I 1999 1679 84 1900 1615 85 1428ª MBTUH Models Dimensions inches Operating Weight lbs Amps MVB Cat I MVB Cat IV B Ht D E F G NPT H NPT K Ø Cat I K Ø Cat IV M Cat I M Cat IV N CA Ø P R V 504 503 43 32 35 23 3 4 1 2 8 6 14 1 8 14 1 2 6 35 6 2 600 12 754 753 49 38 41 29 3 4 1 2 10 6 16 14 1 2 6 41 6 2 660 12 1104 1003 55 44 47 35 3 4 1 1 4 2 1 2 10 6 16 14 1 2 6 47 6 2 72...

Page 5: ...0 Unobstructed Front Open 24 Vent Stack Indoor 1 1 Vent Cap Outdoor 12 12 CLEARANCES MVB Model Water Hardness Soft Medium Hard HP Amps HP Amps HP Amps 503 504 1 4 6 1 4 6 3 4 11 753 754 1 4 6 1 2 7 3 4 11 1003 1104 1 4 6 1 2 7 1 14 1253 1 2 7 1 14 1 14 1503 1504 3 4 11 1 14 1 14 1753 1 14 1 1 2 15 1 1 2 15 2003 2004 1 14 1 1 2 15 1 1 2 15 Do not install on carpeting Note Local codes may require in...

Page 6: ... CATEGORY I WATER HEATERS TYPE WH MVB Model Flow Rates Pressure Drops Minimum Flow Maximum Flow 20 F 30 F GPM P FT T F GPM P FT T F GPM P FT GPM P FT 504 50 2 8 17 100 11 3 8 N A N A 28 1 4 754 50 3 5 25 100 13 8 13 64 6 1 42 3 0 1104 60 6 3 30 113 18 6 16 90 12 6 60 6 3 1504 82 12 6 30 113 22 2 22 N A N A 82 12 6 2004 109 25 5 30 113 27 2 29 N A N A 109 25 5 CATEGORY IV BOILERS WATER HEATERS TYPE...

Page 7: ... 600 1 400 1 244 1 120 1 018 933 862 800 747 1500 15 273 7 636 5 091 3 818 3 055 2 545 2 182 1 909 1 697 1 527 1 388 1 273 1 175 1 091 1018 1999 20 353 10 177 6 784 5 088 4 071 3 392 2 908 2 544 2 261 2 035 1 850 1 850 1 566 1 454 1 357 MVB Input Recovery Rates GPH 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150 500 5 091 2 545 1 697 1 273 1 018 848 727 636 566 509 463 424 392 364 339 750 7 636...

Page 8: ...Boiler Controller TempTracker Mod up to 16 boilers Y 200 up to 40 boilers LonWorks optional Hot Surface Ignition System 1 try standard on cat IV 3 try standard on cat I High Low Gas Pressure Switches Blocked Vent and Air Pressure Switches High Limit Switch Manual Reset Fixed Manual Reset Adjustable Automatic Reset Adjustable Low Water Cut Off 24V With Manual Reset and Test Buttons Flow Switch Modu...