NOTE:
If you touch the Lamp use denatured alcohol and a soft cloth to clean the Lamp. If you
do not clean the Lamp the fingerprints will become etched into the glass which will diminish
UV output and may cause premature lamp failure.
NOTE:
Lamps and Quartz Sleeves should be handled with care. Lamps and Quartz Sleeves
are not warranted against breakage and damage.
WARNING:
Do not install the Lamp at an angle (even a slight angle); this may cause a U
shaped crack at the end of the Quartz Sleeve, or possible breakage of the Lamp. If this
should happen, do not proceed with the installation. Purchase a new Quartz Sleeve or Lamp
from your dealer and refer to the proper installation instructions.
NOTE:
Do not force the Lamp into the Quartz Sleeve.
NOTE:
To achieve the optimum kill rates UV must run continuously. Constant "On and Off"
shorten the life of the lamp and the transformer.
INSTALLING THE LAMP
1.
Unscrew the Davis Connector located behind the Transformer
Cap, this allows your Transformer Cap to spin freely.
2. Plug the Lamp flush into the Lamp End Connector.
If the Lamp is not plugged in all the way it may cause
damage to the unit and is not covered under warranty
.
6.
FINAL LEAK CHECK
:
Do not plug the Sterilizer into power yet, turn on the pump, let water run for
5 minutes and check for leaks.
5.
Tighten the Davis Connector located behind the
Transformer Cap.
3. Insert the Lamp straight into the Quartz Sleeve. Be careful, inserting the Lamp at an angle, even
a slight angle, can cause a "U" shaped crack in the Quartz Sleeve.
4. Screw on the Transformer Cap. Do not over
tighten. This is a connection only and is not in
contact with water.
7. Once a leak test is completed, and there are no leaks, plug the Transformer into a GFCI outlet.
Screw on
Transformer Cap
Screw on
Davis Connector
Davis Connector
Lamp End Connector
Transformer Cap