11
AQUA ULTRAVIOLET 42371 AVENIDA ALVARADO, TEMECULA, CA 92590 TEL: 951-296-3480 FAX: 951-296-3490
8. Screw on the Transformer Cap. Do not over tighten. This is a connection only and is not in
contact with water.
7. Insert the Lamp straight into the Quartz Sleeve. Be careful, inserting the Lamp at an angle, even
a slight angle, can cause a "U" shaped crack in the Quartz Sleeve.
6. Plug the new Lamp flush into the Lamp End Connector. If the Lamp is not plugged in all the way
it may cause damage to the unit and is not covered under warranty.
5. Disconnect the Lamp End Connector
from the old Lamp. Use only Genuine
Aqua Ultraviolet Lamps or the warranty is voided.
4. Slide Lamp out, be careful not to slide the Lamp out at an angle, even a slight angle, this
may cause a “U” shaped crack at the end of the Quartz Sleeve, or possible breakage
of the Lamp.
3. Unscrew the Transformer Cap.
2. Unscrew the Davis Connector located behind the
Transformer Cap, this allows your Transformer Cap to
spin freely.
1. Unplug the UV from the power source and turn off the pump.
MAINTENANCE
CAUTION: Always turn off the pump and disconnect electricity from the unit prior to
any maintenance.
Davis Connector
TM
Quartz Cap
Lamp
Transformer Cap
Lamp End Connector
TM
Unscrew Transformer Cap
Unscrew Davis Connector
Changing the Lamp
10. FINAL LEAK CHECK: Do not plug the Sterilizer into power yet, turn on the pump, let water run
for 5 minutes and check for leaks.
11. Once a leak test is completed and there are no leaks, plug the Transformer into a GFCI outlet.
9. Tighten the Davis Connector located behind the Transformer Cap.