| 14
8. Repairs
Repairs may only be carried out by an authorised service centre.
9. Recommendations
Only install the pump in a lockable room, out of the reach of
children.
Ensure the motor’s cooling. The installation site must be dry and
well ventilated.
Never obstruct the air supply to the fan by putting any objects on
the pump or too close to the pump.
10. Technical Data
Technical Data at 50 Hz
AQUA Splash 4 + 5
AQUA Splash 7
Inlet Sa/Outlet Da (nozzle)
Ø32/Ø32
Ø38/Ø38
Recommended inlet/outlet, hose, d
1 ¼/1 ¼
1 ½/1 ½
Power input P
1
(kW) 1~ 230 V
0.35
0.45
Power output P
2
(kW) 1~ 230 V
0.18
0.25
Rated current (A) 1~ 230 V
1.95
2.30
Weight (kg)
5.40
5.50
Type of motor enclosure
IP X5
Class of insulation
F
Motor speed approx. (rpm)
2840
Max. continuous sound pressure
level dB(A)
≤
70
1)
Max. water temperature (°C)
40 (60)
*)
Max. casing pressure (bar)
2,5
For standard voltage according to DIN IEC 60038 and
DIN EN 60034 (Euro voltage).
Suitable for continuous operation at 1~ 220-240 V.
Tolerances ± 5%.
1)
Measured with a phonometer according to DIN 45635.
*) Explanation of water temperature 40 (60) °C:
40 °C:
max. water temperature as certi
fi
ed by the GS approval.
(60) °C:
pump in its current design is however usable/designed for a max. water temperature of 60 °C.
Subject to technical modi
fi
cations!
D42.02.213-P
D42.02.214-P
Caution
!