Installation, Operation and Maintenance Manual
Long Term Non-Use
If the RO fi ltration system is left unused for long periods (>30 days), follow this procedure:
A) Open faucet to drain tank and turn off feedwater valve. Wait fi ve minutes for RO assembly to depressurize.
B) Remove all cartridges. Turn cartridges upside down in sink or container to drain out as much water as
possible.
C) Place cartridges in a plastic bag with air tight seal and store in refrigerator. Cartridges must not be al-
lowed to freeze or permanent damabe may occur.
D) When RO fi ltration system is ready to be put into service, reinstall cartridges in the RO assembly
heads and sanitize storage tank as described in Section 4. The RO assembly can also be sanitized at
this time, if desired.
E) Follow start up procedure outlined in Section 4.