background image

 

2   

 

 
 

 

GPH of Water @ Total Feet Of Lift 

MODEL 

HP 

0 ft. 

5 ft. 

10 ft.   

15 ft.   

20 ft. 

Max. Lift 

APC3000 

1/3 

1800 

1560 

1320 

960 

240 

21 ft. 

 

Safety Information

 

 

 

 

W

ARNING

Wear safety goggles at all times when working with 

pumps. 

 

 

 

DANGER

Do not pump flammable or explosive liquids such as 

oil,

 gasoline

,

 

kerosene

,

 

ethanol,

 etc

. Do not use in the 

presence of flammable or explosive vapors. Using this pump with or 
near flammable liquids can cause an explosion or 
fire

,

 resulting in property 

damage

,

 serious personal 

injur

y,

 and/or death.

 

 

 

 

DANGER

:

 

ALWA

YS disconnect the power to the 

pump before ser

vicing.

 

 

 

 

DANGER

Do not touch the motor housing during operation.  The 

motor is designed to operate at high temperatures. Do not 
disassemble the motor housing.

 

 

 

 

W

ARNING

This unit is designed only for use on 115 volts (single 

phase), 60 Hz, and is equipped with an approved 3-conductor 
cord and 3-prong grounded plug. Do not remove the ground pin 
under any circumstances. The 3-prong plug must be directly 
inserted into a properly installed and grounded 3-prong, 
grounding-type receptacle. Do not use this pump with a 2-prong 
wall outlet. Replace the 2-prong outlet with a properly grounded 
3-prong receptacle (a GFCI outlet) installed in accordance with 
the National Electrical Code and local codes and ordinances. All 
wiring should be performed by a qualified electrician.

 

 

 

 

DANGER

Do not handle the pump or pump motor with wet 

hands or when standing on a wet or damp 
surface

,

 or in w

ater before 

disconnect the power.

 

 

 

 

W

ARNING

Release all pressure and drain all w

ater from the system 

before ser

vicing any component.

 

 

WARNING

Protect the electrical cord from sharp objects, 

hot surfaces, oil, and chemicals. Avoid kinking the cord. Do not 
use damaged or worn cords.

 

 

 

 

 

 

W

ARNING

Secure the discharge line before starting the pump. 

An 

unsecured discharge line will whip,

 possibly 

causing personal injur

y,

 and/or 

property damage

.

 

 

WARNING

Failure to comply with the instruction and 

designed operation of this unit may void the warranty. 
ATTEMPTING TO USE ADAMAGED PUMP can result in property 
damage, serious personal injury, and/or death. 

 

 

 

 

 

W

ARNING

:

 Ensure that the electrical circuit to the pump is 

protected by a 10 Amp fuse or circuit breaker.

 

 

 

 

W

ARNING

Extension cords may not deliver sufficient voltage to 

the pump motor. Extension cords present a life threatening safety 
hazard if the insulation becomes damaged or the connection 
ends fall into w

ater. 

The use of an extension cord to power 

this pump is not per

mitted.

 

 

 

 

 

CAUTION

Do not lift the pump by the power cord.

 

 

 

 

 

 

 

 

 

Performance

 

 

Summary of Contents for APC3000

Page 1: ...1 APC3000 AUTOMATIC POOL COVER PUMP OPERATIONS MANUAL WWW ECOAQUAPRO COM ...

Page 2: ...ptacle a GFCI outlet installed in accordance with the National Electrical Code and local codes and ordinances All wiring should be performed by a qualified electrician DANGER Do not handle the pump or pump motor with wet hands or when standing on a wet or damp surface or in w ater befor e disconnect the po wer W ARNING Release all pr essur e and dr ain all w ater from the system befor e ser vicing...

Page 3: ...low all local electrical and safety codes along with the National Electrical Code NEC In addition all Occupational Safety and Health Administration OSHA guidelines must be followed IMPORTANT This pump is made of high strength corrosion resistant materials It will provide trouble free service for a long time when properly installed maintained and used However inadequate electrical power to the pump...

Page 4: ... has not been tested or approved for use in salt water marine areas This pump is not designed to function as a permanently installed sump pump It is also not engineered to be run continuously as a fountain or waterfall pump Do not use where water recirculates Features Operating water depth minimum 2 in TOOLS REQUIRED MATERIALS REQUIRED NOT INCLUDED NOTE The hose and hose kit are not shown to scale...

Page 5: ...TENTS NOTE The adaptor is not shown to scale Part Description A Pump B 3 4 in garden hose adaptor SPECIFICATIONS Power supply 115V 60 HZ 10 Amp Circuit Liquid Temp Range 35 F to 77 F 1 25 C Discharge 1 in Male NPT or 3 4 in garden hose thread ...

Page 6: ...ed to the adaptor B If you would prefer to use a 1 1 4 in hose kit not included in order to pump water away more quickly Securely attach the hose kit not included to the adaptor B Operation NOTE Make certain you unwind the garden hose completely Kinks in the hose will restrict the pump preventing it from priming which is the first step to pumping water This pump has water detector sensors As long ...

Page 7: ...drain the water out of the garden hose keep the end of the hose out of the water and plug in the power cord restarting the pump Care and Cleaning CAUTION Always use the handle to lift the pump Never use the power cord to lift the pump To avoid skin burns unplug the pump and allow time for it to cool after periods of extended use Do Do Not When the power is disconnected inspect the pump inlets and ...

Page 8: ... water sensors and impeller 1 Pull the snap fittings on the pump housing and remove the pump filter base 2 Pull the cap up along the pump housing 3 Clean the debris and contamination around the sensor probes TO CLEAN THE PUMP CLOGGED WITH DEBRIS ...

Page 9: ...r blockage has locked the impeller 1 Replace the fuse 2 Reset the breaker 3 Secure the plug 4 Clean the plug prongs 5 Replace the pump 6 Allow the water level to rise to 2 in or more 7 Remove the blockage The pump is unable to pump out water 1 The screen is blocked 2 The hose is kinked bent sharply or coiled 3 There is airlock 4 The hose length is too long 5 The impeller is loose on the shaft 6 Th...

Page 10: ...pecific legal rights and you may also have other legal rights which vary from state to state In no event whether as a result of breach of contract warranty tort including negligence or otherwise shall its suppliers be liable for any special consequential incidental or penal damages including but not limited to loss of profit or revenues loss of use of the products or any associated equipment damag...

Reviews: