4.  Technical data cooling unit 
 

 

Titan 200 

Titan 600 

Titan 1600 

Titan 2200 

Power (compressor) 

0.1 HP 

0.25 HP 

0.5 HP 

 

1 HP 

Power uptake (watts) 

160 w 

345 w 

480 w 

550 w 

Cooling power (watts) 

200 w 

600 w 

800 w 

1,600 w 

For aquaria up to  

 (

 T max.  5 °C) 

 

250 l 

 

750 l 

 

1,500 l 

 

2,500 l 

Recommended water flow 
(litres/h) 

     
250 – 1,200 

    
1,000 – 2,500  

   
1,200 – 3,000  

  
1,500 – 4,000 

Weight 

13 kg 

18.6 kg 

19.3 kg 

19.8 kg 

Cooling gas 
  

Quantity of coolant 

 

R 134 a 

  

150 g                    150 g                          300 g                   640 g   

 

Dimensions (l x w x h) 

 

43 x 25.5 x 38 cm 

 

45.7 x 33 x 43 cm      48 x 35.5 x 48 cm  56 x 38 x 48 cm  

 

Heat exchanger 

Titanium 

Temperature controller 

digital, accuracy 1 °C, set point adjustion in 1 °C step 

 

Available spare parts: Please refer to www.aqua-medic.de. 

 

5.  Maintenance 

 
The cooler has the same requirements with respect to maintenance like conventional cooling units (refrigerators 
etc.). Maintenance and/or repairs should be done exclusively either by a service engineer or by the manufacturer.  

 

Clean the filter sieves and air-cooled condenser regularly. 

Beforehand, unplug the unit. The filter sieves to 

protect the condenser from dust are located on the side and front of the housing. To clean the front filter, the 

screw at the bottom of the housing has to be loosened. The side filters are clicked in.  

 
If the condenser is still soiled, the housing is opened with a screwdriver and the lamellas of the condenser are 

carefully freed from adhering dust, for example with compressed air. 

 

Without this regular cleaning, fan and compressor may be irreversibly damaged. We recommend to flush the heat 

exchanger thoroughly once a year to remove any muddy parts. 

 

6.  Warranty conditions  

 

AB Aqua Medic GmbH grants the first-time user a 24-month guarantee from the date of purchase on all material 

and manufacturing defects of the device. Incidentally, the consumer has legal rights; these are not limited by 

this warranty. This warranty does not cover user serviceable parts, due to normal wear & tear ie: impellers or 

drive wheels etc. The original invoice or receipt is required as proof of purchase. During the warranty period, we 

will  repair  the  product  for  free  by  installing  new  or  renewed  parts.  This  warranty  only  covers  material  and 

processing faults that occur when used as intended. It does not apply to damage caused by transport, improper 
handling, incorrect installation, negligence, interference or repairs made by unauthorized persons. 

In case of a 

fault with the unit during or after the warranty period, please contact your dealer. All further steps 

are clarified between the dealer and AB Aqua Medic. All complaints and returns that are not sent to 

us  via  specialist  dealers  cannot  be  processed.

  AB  Aqua  Medic  is  not  liable  for  consequential  damages 

resulting from the use of any of our products.  

 

AB Aqua Medic GmbH - Gewerbepark 24 - 49143 Bissendorf/Germany 

- Technical changes reserved – 03/2021/v3 

 

 

 

 

 

 

 

 

 

 

 

 

Summary of Contents for Titan 1600

Page 1: ...ES Manual de instrucciones Por favor lea el manual cuidadosamente P 14 16 IT Manuale Operativo Leggere il manuale attentamente in modo P 17 19 PL Instrukcja U ytkownika Prosimy dok adnie przeczyta pr...

Page 2: ...hl sse sind frei abstr men k nnen Eine Umgebungstemperatur von 35 C darf nicht berschritten werden 2 K hlaggregat an den Stutzen an den Wasserkreislauf anschlie en Es wird empfohlen das Ger t unterhal...

Page 3: ...erung ist damit abgeschlossen Der Kompressor hat eine Einschaltverz gerung von bis zu drei Minuten Boost Funktion Durch Dr cken der BOOST Taste Abb 1 Nr 5 wird die L fterleistung gesteigert Dadurch is...

Page 4: ...ie die Lamellen des Kondensors vorsichtig zum Beispiel mit Druckluft von anhaftendem Staub Ohne diese regelm ige Reinigung k nnen L fter und Kompressor irreparabel besch digt werden Wir empfehlen den...

Page 5: ...from the back where the water connections are placed The environmental temperature should not exceed 35 C 2 The cooling unit has to be connected at the connecting pieces to a closed water cycle It is...

Page 6: ...oint is saved by pressing the Set button again Programming is now complete The compressor has a switch on delay of up to three minutes Boost function Pressing the BOOST button Fig 1 No 5 increases the...

Page 7: ...er and the lamellas of the condenser are carefully freed from adhering dust for example with compressed air Without this regular cleaning fan and compressor may be irreversibly damaged We recommend to...

Page 8: ...re ambiante ne doit pas exc der 35 C 2 Le refroidisseur doit tre connect en circuit ferm l eau refroidir Ceci s effectue l aide de tuyau ou tubes en plastique des pi ces suppl mentaires sont disponibl...

Page 9: ...ntenant termin e Le compresseur a un d lai de mise en marche pouvant aller jusqu trois minutes Fonction Boost Une pression sur le bouton BOOST Fig 1 n 5 augmente les performances du ventilateur Cela p...

Page 10: ...r et le compresseur peuvent tre endommag s de mani re irr versible sans ce nettoyage r gulier Une fois par an nous vous recommandons de nettoyer le circuit de refroidissement afin d y ter toutes les b...

Page 11: ...achterzijde vrij kunnen uitstromen waar de water aansluitingen zich bevinden De omgevingstemperatuur mag niet hoger zijn dan 35 C 2 De koelunit dient verbonden te worden aan een gesloten watercirculat...

Page 12: ...e drukken Het programmeren is nu gereed De compressor heeft een aanschakel vertraging van ca 3 minuten Boost functie Door de BOOST knop in te drukken Fig 1 No 5 zal de ventilator output verhoogd worde...

Page 13: ...van de condensor vrij gemaakt worden van vast zittend vuil b v met pers lucht Zonder deze regelmatige schoonmaak kan de ventilator en de compressor onherstelbaar beschadigd worden We raden aan de war...

Page 14: ...miento Por tanto es esencial una ventilaci n suficiente La temperatura medioambiental no exceder de 35 C 2 Las unidades de fr o deben ser conectadas a las piezas de conexi n para un ciclo de agua cerr...

Page 15: ...alla entre el segundo y el tercer digito de la pantalla El compresor tiene un retardo de conexi n de hasta tres minutos Funci n Potencia Al pulsar el bot n BOOST Fig 1 n 5 se incrementa la potencia de...

Page 16: ...comprimido A continuaci n abra la carcasa con un destornillador y limpie de polvo las aspas del condensador cuidadosamente Sin esta limpieza regular el ventilador y el compresor pueden quedar da ados...

Page 17: ...poter fuoriuscire dal retro dove si trovano gli attacchi idraulici La temperatura ambientale non deve superare i 35 C 2 L unit di raffreddamento deve essere collegata ai raccordi a un ciclo dell acqua...

Page 18: ...e Set La programmazione ora completa Il compressore ha un ritardo di accensione fino a tre minuti Funzione Boost Premendo il pulsante BOOST Fig 1 n 5 si aumenta la potenza del ventilatore Ci consente...

Page 19: ...l condensatore vengono accuratamente liberate dalla polvere aderente ad esempio con aria compressa Senza questa pulizia regolare la ventola e il compressore potrebbero subire danni irreversibili Si co...

Page 20: ...e znajduj si przy cza musi by sprawnie wentylowane z okolic ch odziarki Ch odziarka nie mo e by instalowana w miejscach gdzie temperatura otocznia jest wy sza ni 35 C 2 Urz dzenie pracuje w obiegu zam...

Page 21: ...rki ma czas na za czenie si do 3 minut Funkcja Boost Wciskaj c przycisk Boost rys 1 nr 5 zwi ksza si wydajno pracy wentylatora Ch odziarka zaczyna oddawa ciep o szybciej ale jest przez to znacznie g o...

Page 22: ...y rozkr ci a lamelki nale y wyczy ci przy pomocy spr onego powietrza Bez okresowego czyszczenia wentylator i spr arka mog zosta trwale uszkodzone Zalecamy minimum raz do roku dok adnie przep uka wymi...

Page 23: ...US Titan R 134 a 1 Aqua Medic Titan 200 600 1600 2200 Titan 1600 2200 2 1 35 C 2 3 Titan 200 200 1 500 Titan 600 500 2 000 Titan 1600 800 2 500 Titan 2200 2000 4 000 4 1 230 Titan 200 Titan 600 POWER...

Page 24: ...24 3 Titan 1 Titan 200 2200 1 2 3 4 5 6 7 POWER SET C F C Set SET 1 C Set Boost BOOST 1 5 Boost 2 24 7 SET 1d 2d 1d 1 C 2d 2 C 1d 2d 1 C 1 C 2d 2 C 1 5 C 1 5 C 15 15 0 1 C...

Page 25: ...50 1200 1000 2500 1200 3000 1500 4000 13 18 6 19 3 19 8 R 134 a 150 150 300 640 43x25 5x38 x x 45 7x33x43 x x 48x35 5x48 x x 56x38x48 x x Titan 1 C 1 C www aqua medic de 5 AB Aqua Medic GmbH 24 49143...

Page 26: ...26...

Reviews: