background image

Manufactured by: 

 

JOY POOL SYSTEMS 

 

ACN 141 035 172  ABN 66 141 035 172 

Website: www.aquajoy.com.au 

Unit 21, 2 Richard Close 

E-mail: [email protected] 

NORTH ROCKS  NSW  2151 AUSTRALIA  Ph: +61 2 9630 5011  Fax: +61 2 9683 4750 

  

                                                                                                             

 

 

SALTWATER CHLORINATOR 

 

OWNERS HANDBOOK 

 

AUTO DELUXE & STANDARD 

 
 

Summary of Contents for 1SAJ150

Page 1: ...141 035 172 ABN 66 141 035 172 Website www aquajoy com au Unit 21 2 Richard Close E mail sales aquajoy com au NORTH ROCKS NSW 2151 AUSTRALIA Ph 61 2 9630 5011 Fax 61 2 9683 4750 SALTWATER CHLORINATOR...

Page 2: ...AQUAJOY is switched on Please check that the pump is functioning correctly before assuming that the AQUAJOY unit is not working Your AQUAJOY is fitted with a light which indicates when the unit is swi...

Page 3: ...installed by competent personnel to the instructions contained in this manual Power Pack is to be installed according to AS NZ 3000 2000 and located outside pool Zone 2 area Servicing should only be a...

Page 4: ...d not be operated by personnel eg operating front panel switches adjusting time clock safety cutout cleaning cells etc when the surrounding area is damp In addition personnel should not operate the un...

Page 5: ...DOUBT ABOUT THE SAFETY OF THE UNIT OR IF THE UNIT MALFUNCTIONS ADOPT THE FOLLOWING SAFETY INSTRUCTIONS Turn off the power to the unit at the power point Disconnect the power cord and call for service...

Page 6: ...separation between mains and extra low voltage parts All insulating panels are in place and terminal connections are tight Earth pin of power cord to all external metal parts of the chlorinator to hav...

Page 7: ...ART UP PROCEDURE 5 CHLORINE PRODUCTION TEST 6 GENERAL INFORMATION ON WATER CARE 7 Filtration 7 Chlorination 7 pH 7 Conclusions 8 MAINTENANCE 8 Cleaning of the Cell 8 Adding Salt 9 Power Pack Maintenan...

Page 8: ...piled to assist you on Basic Pool Care AQUAJOY SALT WATER CHLORINATOR MODELS 1 STANDARD 2 AUTO DELUXE Time Clock AQUAJOY STANDARD Ideal for established and new pools where a time clock is already fitt...

Page 9: ...y over riding the time clock normal position AUTO when in time clock mode D Chlorine production dial Anticlockwise to reduce clockwise to increase E Time clock see page 12 F 3A Circuit Breaker A Cell...

Page 10: ...s in winter 2 MOUNT THE POWER PACK a Screw mounting bracket to wall or post with slots facing upwards within 1 5 metres of the power outlet and within 1 5 metres of the Filter Return to Pool Line b Pl...

Page 11: ...lied already connected to the Terminal Box under the Power Pack b If it is necessary to disconnect the cell lead re assemble as follows i Attach Blue wire of cell lead to Blue wire of Terminal Box ii...

Page 12: ...ow 24 hours 3 Valves re opened INSTALLATION DIAGRAM NOTE WATER MAY FLOW EITHER WAY THROUGH INLET OUTLET PORTS ON CELL CELL MAY BE REVERSED AS SHOWN IN DIAGRAM GAS AND ELECTRIC HEATERS REQUIRE CELL INS...

Page 13: ...sector CHLORINE PRODUCTION TEST 1 Turn on Filter and Chlorinator 2 Place thumb over chlorine test vial and place next to return to pool outlet 3 Allow water to fill vial and replace thumb over vial be...

Page 14: ...tration causes excessive electricity bills and wear and tear on equipment CHLORINATION Chlorine is required to react with the debris removing stains by oxidation and to sterilise the water of harmful...

Page 15: ...ubsequently the production of Chlorine It may also damage the anode electrodes and cause damage beyond repair 1 Switch off the filtration and Chlorinator and close valves 2 Unscrew cap in an anti cloc...

Page 16: ...kg bag of salt into pool at shallow end Ensure Chlorine production dial is turned down 2 Allow salt to dissolve and increase Chlorine output Inspect Chlorine Monitor If not in normal sector repeat as...

Page 17: ...100 110 25 000 12 5 25 37 5 50 62 5 75 87 5 100 112 5 125 137 5 30 000 15 30 45 60 75 90 105 120 135 150 165 40 000 20 40 60 80 100 120 140 160 180 200 220 45 000 22 5 45 67 5 90 112 5 135 157 5 180...

Page 18: ...and WINTER sectors and each sector has 3 coloured areas YELLOW GREEN ORANGE see colour coding in lower left hand corner and the monitor needle position will vary according to the condition of your po...

Page 19: ...white tappets The dial is for 24 hours and each tappet represents 15 minutes The correct time is set at the white indicator arrow situated at 2 0 O clock on the black face To set the Time Clock push...

Page 20: ...er levels is low or cell is clogged with scale Short intervals between backwashes Ineffective backwashing Body fat or oil build up on pads With Diatomaceous earth filters the cause may be insufficient...

Page 21: ...TRUCTIONS CORRECTLY Should your Pump Motor fail or other problems do not allow you to operate your AQUAJOY in the normal manner Sodium Hypochlorite liquid chlorine may be added to keep the pool steril...

Page 22: ...NTENANCE DATE CLEANED METHOD USED RESULT POWER PACK TERMINAL BOX FASTENINGS DATE CHECKED NEEDED ATTENTION YES NO Connections on Terminal Box should be checked at three 3 monthly intervals to ensure th...

Page 23: ...rectifier devises JOY POOL SYSTEMS shall not be liable for loss of profits or benefits indirect special consequential or other similar damages arising out of any breach of warranty or otherwise PLEASE...

Page 24: ...ctured by JOY POOL SYSTEMS ACN 141 035 172 ABN 66 141 035 172 Unit 21 2 Richard Close NORTH ROCKS NSW 2151 AUSTRALIA Website www aquajoy com au E mail sales aquajoy com au Ph 61 2 9630 5011 Fax 61 2 9...

Reviews: