background image

PROFESSIONAL
POND
PRODUCTS

DRUMFILTER XL

Instruction Manual 

Summary of Contents for DRUMFILTER XL

Page 1: ...PROFESSIONAL POND PRODUCTS DRUMFILTER XL Instruction Manual ...

Page 2: ......

Page 3: ...option Waste gutter Ø110mm cleaning pump connection 1 female thr Cleaning nozzles connection 1 female thr 2 x Ø110 OUTLET Controller cable fuse cleaning pump solenoid valve connection UV C connection optional ON OFF switch 230V power supply ...

Page 4: ...ages Always comply to the national and international safety regulations apart from the safety instructions in this manual GENERAL FUNCTION The drumfilter will filter solid waste particles from the water The water will enter the filter at this inlet chamber and then flow into the drum Waste particles will deposit on the inside of the drum which will decrease the output flow of clean water through t...

Page 5: ...itted with 3 Ø110 mm inlets If you do not use all 3 of them we recommend to keep the middle inlet closed The left and right inlets will not enter the drum directly but first hit the walls of the inlet chamber which allows a more quite flow into the drum When you use all 3 inlets we recommend to use the middle inlet for the pipe with the least flow like the skimmer or the bottom drain that is insta...

Page 6: ...ot solvent weld PVC glue PP Use flexible waste fittings or fittings with a rubber gasket ask your dealer for advise The controller unit is splash water proof IP65 and should be mounted dry and protected from direct sunlight normal position high water level in drum chamber controller will not clean active position low water level in drum chamber controller will clean Level switch in gravity applica...

Page 7: ...n the left opening Push the connector through the mounting bracket in the inlet chamber Please keep in mind that the level switch must be rotated 180 degrees in regards to the gravity position Then put the nut over the connector and screw it on the level switch Push the connector through the opening and push it through the rubber plug The small hole of the plug can be widened with a sharp knife to...

Page 8: ...fter about 2 seconds 2 The power outlet for the cleaning pump solenoid valve will be provided with 230V to provide the spray nozzles with water This will rinse off the waste particles that have been collected on the inside of the drum The dirty water will exit the filter through the waste gutter outlet The cleaning process stops as soon as the level switch has returned to its normal position plus ...

Page 9: ...ON WARNING Be sure you have removed the power plug from the wall outlet before you open the controller Not following these safety precautions can lead to serious injuries through electric shock You are responsible for opening the controller unit SAFETY OPTIONS The cleaning process will be activated and stopped with the level switch There are however circumstances that can negatively influence this...

Page 10: ...atever reason it will try to move anyhow This will cause a higher amp use then in a normal unblocked situation As soon as a certain threshold is exceeded the controller will rotate the drum in the opposite direction as an attempt to get rid of possible object that could block the drum If this offers no solution and the threshold value is still exceed ed the controller will stop the motor and the c...

Reviews: