2 1 |
P a g e
AQUA FLO Rack-Mount UV System Specifications
AQUA FLO EQUIPMENT SPECIFICATIONS
RACK-MOUNT UV SYSTEMS
MODEL
GEN4-8R1
(40030061N)
GEN5-8R1
(40030050N)
GEN4-8R12
(40030062N)
GEN5-8R12
(40030051N)
GENH4-13R2
(40030063N)
GENH5-13R2
(40030052N)
GENH4-13R22
(40030064N)
GENH5-13R22
(40030053N)
Flow Rate
(@30mJ/cm
2
)
8.0 gpm
15.0 gpm
30.3 lpm
56.8 lpm
1.82 m
3
/hr
3.4 m
3
/hr
Flow Rate
(@40mJ/cm
2
)
5.6 gpm
12 gpm
21.2 lpm
45.4 lpm
1.3 m
3
/hr
2.7 m
3
/hr
Filter Housing - 1
5 micron sediment
26235
5 micron sediment
26235
5 micron sediment
26239
5 micron sediment
26239
Filter Housing - 2
N/A
high capacity carbon
26256
N/A
high capacity carbon
26256
Port Size
1”FNPT (filter side) / 1” MNPT (UV side)
Electrical
90-265V/50-60Hz.
Plug Type
American: NEMA 5-15P
Lamp Power (Watts)
20 (standard-output lamp)
45 (high-output lamp)
Power (Watts)
23 (21 @ 230V.)
57 (48 @ 230V.)
Replacement Lamp
40040096
40040020
Replacement Sleeve
40040042
Reactor
Dimensions
8.9 x 50.8 cm
(3.5 x 20”)
Chamber
Material
Polished 316L Stainless Steel, A249 Pressure Rated Tubing (to ASME specs)
Controller
Dimensions
17.2 x 9.2 x 7.6 cm (6.8 x 3.6 x 3”)
21.8 x 10.7 x 8.9 cm (8.6 x 4.2 x 3.5”)
Operating
Pressure
0.7-6.9 bar (10-100 psi)
Operating Water
Temperature
2-40° C (36-104° F)
UV Monitor
OPTIONAL (optional UV module (40040002) for GEN5, (40040003) for GENH5 sold separately)
Solenoid Output
YES (optional solenoid module (40040006) sold separately)
Dry Contacts
YES (remote alarm module (40040008) sold separately)
4-20mA Output
YES (4-20mA module (40040007) sold separately)
Lamp Change Reminder
(audible & visual)
YES
Lamp Out Indicator
(audible & visual)
YES
Shipping Weight
11.3 kg
(24.8 lbs)
19.0 kg
(41.8 lbs)
16.4 kg
(36.2 lbs)
20.3 kg
(44.8 lbs)