Soft Alarms: The following remaining errors give a 15 second audible chirp only
System Display
Problem
Resolution
The module indicated is
no longer communicat-
ing to with the system.
Ensure all modules are
connected properly to the
system and to each other.
Modules can be tested indi-
vidually by plugging in one
at a time and cycling power
to the system.
Replace any module that is
not detected when plugged
directly into the controller.
COMING SOON
Warning: After any hard alarm, the home or facility should be disinfected. Follow the steps un-
der the “System Disinfection” heading.
Temperature Management Devices
Your AQUA FLO AQUA FLO system is designed to run continuously to ensure optimal disinfection.
However, during periods when no water is drawn through the system, the energy from the
disinfection process can cause the temperature of the water inside the chamber to rise. In
extreme situations elevated water temperature or the fluctuation in temperature can lower the
output of the UV lamp. In these cases, or if the elevated water temperature is a nuisance, AQUA
FLO recommends one of the following forms of temperature management devices.
Cooling Fan
Designed for use on the AQUA FLO-HO systems, the fan runs continuously to cool
the water by forced convection. The long-life fan is powered independently using
a compact modular power adapter that operates from 90-265V (47-63Hz). Order
PN 40040009 (only fits GENH4/GENH5 systems).
Temperature Relief Valve (TRV)
On reaching a higher temperature, the TRV is designed to drain a small amount
of water to allow fresh, cooler water to enter the system. The TRV works without
power and comes complete with 10’ of drain line. Order PN 40040100 for 1”
ports.