background image

4

5

(B) SAFETY GUIDELINES

 

(CONTINUED)

—

  

To avoid 

possible electric shock, extra care should be taken since water may be present near electrical equipment. Unless specifically referred to  

  in these instructions, do not attempt repairs yourself. Do not plug the unit in if any electrical surfaces or electrical parts are wet.

—

  

DO NOT LOOK DIRECTLY AT UV LAMP WHEN LAMP IS ON

. UV light can cause serious burns to eyes and skin.

—

  

Do not

 operate the UV lamp outside the UV disinfection chamber.

—

  

Do not

 use this unit for any purpose other than its intended use for potable water disinfection. The use of attachments not recommended,  

  approved or sold by the manufacturer may result in improper performance of the unit or an unsafe condition and void the product warranty.

—

  

Do not

 operate the system if it has a damaged electrical cord or plug, is malfunctioning, or has been damaged in any way.

—

  

Do not

 touch the lamp or quartz dome with dirty or moist hands. Hold the lamp and dome by the ends with soft dry gloves or cloth.

—

  Before any cleaning or maintenance on the system, always unplug the unit from the power source.

—

  Disconnect power cable from the power outlet by holding the plug. Never pull the cord.

—

  To comply with the National Electrical Code and to provide additional protection from the risk of electric shock, this system should only be  

  connected to a properly grounded, grounding-type controller receptacle that is protected by a Ground Fault Circuit Interrupter (GFCI).

—

  Ensure that the lamp connector ground wire is connected to the grounding stud on the chamber.

—

  Installation of the UV disinfection system and water filter will interrupt electrical grounding continuity of your plumbing system. For directions  

  on restoring the electrical grounding continuity, consult a certified electrician

—

  Protect your unit from freezing and weather elements.

WARNING

To ensure continuous protection, 

UV LAMP MUST BE  

REPLACED ANNUALLY

. After 1 year of use, it will no  

longer provide effective disinfection even though it stays lit.

WARNING

USE ONLY 

GENUINE

 AQUA FLO AQUV LAMPS. Use of non-

Aqua Flo AQUV UV lamps can result in unsafe drinking water,  

which may lead to illness and/or death, ballast failure or fire, 

and will void your product warranty. (see page 12 for details)

Canature WaterGroup U.S.A. Inc. / Canature WaterGroup Canada Inc. (Canature) has disclosed all known 
risks associated with the product within this manual but cannot disclose risks that are beyond its  
knowledge.

(C) WATER QUALITY REQUIREMENTS

The unit should only be operated with water that meets the following minimum criteria:

—

  

Turbidity/Suspended Solids:

 Ideally less than 1 NTU (Nephelometric Turbidity Unit). A 5 micron sediment filter or better must be installed    

  in the UV system at all times. If the feed water has fine sediment, a finer pre-filter (1 micron or smaller) may be used. If the water has very high    

  turbidity, a back-washable multi-media filter is recommended along with a cartridge type filter.

—

  

Hardness:

 Less than 7 GPG (120 mg/L). Hard water causes scale build-up on the quartz sleeves thereby reducing the UV transmittance in the    

  water and in turn reduced performance. The UV system will work with hard water for a short time after which the scale build-up on the quartz    

  dome will cause reduced disinfection performance (unsafe condition). It is therefore recommended that, for hard water, a water softener should   

  be installed prior to the UV system.

—

  

Iron & Manganese:

 Iron less than 0.3 PPM (mg/L) and Manganese less than 0.05 mg/L is desirable. At higher concentrations, a suitable water  

  conditioner (e.g. an Iron Filter or Greensand filter) should be installed prior to the UV system to prevent iron build-up on the quartz dome that    
  can cause insufficient disinfection.

—

  

Tannins and Colour:

 Water with tannins or colour has low UV transmissivity that reduces UV system performance. The UV system will not work   

  if the water has tannins or colour. A tannin-removal system should be installed for proper disinfection.

Summary of Contents for AQUV AQUV-8R12

Page 1: ...nstalled in accordance with local plumbing codes 3 Test the water periodically to verify that the system is performing satisfactorily 4 Discard small parts remaining after the installation 5 Failure t...

Page 2: ......

Page 3: ...ganisms present in the water supply Simple maintenance continuous disinfection and ultimately safe water AQUA FLO makes it that easy Tested and Certified by CSA Group to CSA Standard B483 1 to NSF ANS...

Page 4: ...eady for use See Fig 1 UV systems are used around the world as a primary disinfectant as it is a natural non chemical environmentally safe technique that is not known to form any harmful disinfection...

Page 5: ...V LAMP MUST BE REPLACED ANNUALLY After 1 year of use it will no longer provide effective disinfection even though it stays lit WARNING USE ONLY GENUINE AQUA FLO AQUV LAMPS Use of non Aqua Flo AQUV UV...

Page 6: ...e installed at the inlet port 8 US GPM The system should be installed indoors in a protected area where the temperature does not fall below 4 C 40 F For optimum performance the system should be wall m...

Page 7: ...k If you have other water filters conditioner installed such as softener iron filter etc the UV system should always be installed as the last step of treatment before the water pipes divide into hot a...

Page 8: ...the filter cartridges Reinsert the new cartridge into the sump and screw the sump back onto the filter Hand tighten only 4 Carefully unpack UV lamp and quartz dome Two o rings come with the quartz dom...

Page 9: ...ugh the plastic making it easy to hook up lamp the white plastic part has a little screw to secure it to the gland nut 11 Remove the nut from the ground stud at the top of the unit Next place the grou...

Page 10: ...and thoroughly flush all outlets until the chlorine smell is minimal 7 You are ready to use the water now F BALLAST FOR AQUV UV SYSTEMS Aqua Flo AQUV advanced micro processor controlled electronic UV...

Page 11: ...rinse sump 4 Remove O rings and replace if they have been in use for a year Otherwise wipe them with a soft cloth or paper towel and clean the groove on which the O rings are seated 5 Apply food grade...

Page 12: ...will re set the lamp change timer to zero and the 3 second beep will confirm that the re set was successful Winterizing Your System To winterize the system unplug the unit first Drain the pre filter...

Page 13: ...AQUV 8 1 8 80127302 Dome O Ring Thicker 1 9 80127301 Gland Nut O Ring Thinner inside nut 1 10 89112 UV Lamp for AQUV 8 1 11 80127402 Lamp Spring 1 12 36053 Pre filter head 1 10 Sump for pre filter 1 P...

Page 14: ......

Page 15: ......

Page 16: ...including any warranty of merchantability or fitness for a particular purpose and excludes all other express or implied warranties to the extent permitted by law For clarity where exclusion is not pe...