12

13

Category

AQUV-8R12 AQUV-8R22

Maximum flow rate @ 30 mJ/cm

2

*

8 gpm / 30 lpm

Maximum flow rate @ 40 mJ/cm

2

*

5 gpm / 19 lpm

Lamp service life

9000 Hours

Lamp Power

35 watt

Power Consumption

35 watt

Annual lamp change timer

Yes

Lamp-ON Indicator

Yes

Audio/Visual alarms

Yes

Chamber material

304 Stainless Steel

Chamber dimensions (D x L)

3.5” x 16.0”

Controller dimensions (L x W x D)

8” x 3” x 2.25”

Inlet/Outlet port size

3/4”NPT

AC supply voltage

120V, 50/60Hz, 0.8A

Maximum operating pressure

100psi

Water temperature range

2 - 40°C (36-104°F)

Shipping Weight

46lb / 21kg

49.5lb / 22.5kg

AQUV-8R12 and 8R22

Item as 

Labelled

PART 

NUMBER

DESCRIPTION

QTY

1

40020068

Ballast, power cord & lamp connector assembly

1

2

80126734

Ballast mounting bolts

2

3

80126718

Ballast mounting nuts

2

4

430335

SS UV Chamber for AQUV-8

1

5

Gland Nut

1

6

89587

Chamber Mounting SS Nut

1

7

36003037

Quartz Dome for AQUV-8

1

8

80127302

Dome O-Ring (Thicker)

1

9

80127301

Gland Nut O-Ring (Thinner) – inside nut

1

10

89112

UV Lamp for AQUV-8

1

11

80127402

Lamp Spring

1

12

36053

Pre-filter head

1

10” Sump for pre-filter

1

Pressure vent button

1

BH Mounting screw

4

BH mounting washer

4

Wrench to open pre-filter housing

1

13

36112

Pre-filter head

1

20” Sump for pre-filter

1

Pressure vent button

1

BH Mounting screw

4

BH mounting washer

4

14

36281

10” 5 micron sediment cartridge

1

15

36029

20” 5 Micron Carbon Block Cartridge

1

16

60010559

Sump O-rings

4

17

80036768

1”x3/4” reducer bushing

1

18

80036770

¾” street elbow

2

19

80030391

¾” Close Nipple

1

20

33611006

1”x2” Nipple

1

21

80127829

¾” x ¾” Flex Tube, 24”

1

22

89589

UV Bracket - Dual Sump

1

SYSTEM

AQUV-8R12

AQUV-8R22

Item #

40030105

40030106

Lamp

89112

89112

Quartz Dome

36003037

36003037

Controller

40020068

40020068

5 Micron Sediment 

Cartridge 10"

36281

5 Micron Carbon Block 

Cartridge 20"

36281

36029

5

8

6

1

4

7

10

11

14

15 16

17

18

19

20

22

23

12

12

12

12

13

13

13

9

2 3

(I) TECHNICAL SPECIFICATIONS

(J) PARTS LIST

 *Dosage based on a UVT value of 96%

Summary of Contents for AQUV AQUV-8R12

Page 1: ...nstalled in accordance with local plumbing codes 3 Test the water periodically to verify that the system is performing satisfactorily 4 Discard small parts remaining after the installation 5 Failure t...

Page 2: ......

Page 3: ...ganisms present in the water supply Simple maintenance continuous disinfection and ultimately safe water AQUA FLO makes it that easy Tested and Certified by CSA Group to CSA Standard B483 1 to NSF ANS...

Page 4: ...eady for use See Fig 1 UV systems are used around the world as a primary disinfectant as it is a natural non chemical environmentally safe technique that is not known to form any harmful disinfection...

Page 5: ...V LAMP MUST BE REPLACED ANNUALLY After 1 year of use it will no longer provide effective disinfection even though it stays lit WARNING USE ONLY GENUINE AQUA FLO AQUV LAMPS Use of non Aqua Flo AQUV UV...

Page 6: ...e installed at the inlet port 8 US GPM The system should be installed indoors in a protected area where the temperature does not fall below 4 C 40 F For optimum performance the system should be wall m...

Page 7: ...k If you have other water filters conditioner installed such as softener iron filter etc the UV system should always be installed as the last step of treatment before the water pipes divide into hot a...

Page 8: ...the filter cartridges Reinsert the new cartridge into the sump and screw the sump back onto the filter Hand tighten only 4 Carefully unpack UV lamp and quartz dome Two o rings come with the quartz dom...

Page 9: ...ugh the plastic making it easy to hook up lamp the white plastic part has a little screw to secure it to the gland nut 11 Remove the nut from the ground stud at the top of the unit Next place the grou...

Page 10: ...and thoroughly flush all outlets until the chlorine smell is minimal 7 You are ready to use the water now F BALLAST FOR AQUV UV SYSTEMS Aqua Flo AQUV advanced micro processor controlled electronic UV...

Page 11: ...rinse sump 4 Remove O rings and replace if they have been in use for a year Otherwise wipe them with a soft cloth or paper towel and clean the groove on which the O rings are seated 5 Apply food grade...

Page 12: ...will re set the lamp change timer to zero and the 3 second beep will confirm that the re set was successful Winterizing Your System To winterize the system unplug the unit first Drain the pre filter...

Page 13: ...AQUV 8 1 8 80127302 Dome O Ring Thicker 1 9 80127301 Gland Nut O Ring Thinner inside nut 1 10 89112 UV Lamp for AQUV 8 1 11 80127402 Lamp Spring 1 12 36053 Pre filter head 1 10 Sump for pre filter 1 P...

Page 14: ......

Page 15: ......

Page 16: ...including any warranty of merchantability or fitness for a particular purpose and excludes all other express or implied warranties to the extent permitted by law For clarity where exclusion is not pe...