CAUTION!

** Install a pressure regulator and water hammer 

arrestor if pressure exceeds maximum rating of 

100 psi at any time. Note: If daytime pressure is 

over 80 psi, night time pressure may exceed  

maximum pressure rating.

 24.00 
 16.00 

 8.50 

 25.60 

 24.00 
 16.00 

 36.69 

 8.50 

AQUV 12R22

AQUV 20R22

(D) INSTALLATION

DIMENSIONS

INSTALLATION NOTES AND CAUTIONS:

—

  The Aqua Flo AQUV Water Disinfection System is designed for installation on the cold water line only at the point of entry (POE). The system must  

  be installed in accordance with all local, state or provincial regulations.

—

  The system requires a constant power supply of 110V AC.

—

  It is strongly recommended to have a dedicated electrical circuit for the UV system. A CSA or equivalent certified surge protector must be installed  

  to protect the ballast from electrical surges. We recommend surge protector rated for a clamping voltage of less than 400 Volts, response time of   

  less than one nanosecond, and energy absorption of at least 600 Joules.

—

  The AQUV-20, AQUV-12 systems have been designed for maximum water flow rates of 20 US GPM (70 liters per minute) and 12 US GPM (45 liters  

  per minute) respectively. If higher flow rates exist occasionally, it is recommended that a flow restricter be installed at the inlet port (12  

 

  US GPM for AQUV-20 and 12 US GPM for AQUV-12.

—

  The system should be installed indoors in a protected area where the temperature does not fall below 4°C (40°F).

—

  For optimum performance, the system should be wall-mounted in a vertical position with the lamp connector at the top. 

—

  It is highly recommended to install bypass piping with a shut-off valve around the unit. This way you can still have water in case you need to  

 

  remove the UV unit for service. 

—

  Provide a minimum clearance of 3 feet above the unit for lamp replacement.

—

  Use only Teflon tape for all connections. Do not use any other sealant on the threads.

NOTICE

Check with your local public works department 

for applicable local plumbing and sanitation 

codes. Follow local codes if they differ from 

the standards used in this manual. Otherwise, 

carefully follow the instructions in this manual. 

Canature is not liable for any non-compliance 

with local requirements

Summary of Contents for AQUV AQUV-12R22

Page 1: ...installed in accordance with local plumbing codes 3 Test the water periodically to verify that the system is performing satisfactorily 4 Discard small parts remaining after the installation 5 Failure to install the system correctly voids the warranty 6 Handle all components of the system with care Do not drop drag or turn components upside down 7 Save these instructions and keep track of your prod...

Page 2: ......

Page 3: ...rganisms present in the water supply Simple maintenance continuous disinfection and ultimately safe water AQUA FLO makes it that easy Tested and Certified by CSA Group to CSA Standard B483 1 to NSF ANSI Standard 61 for material and structural requirements only and to NSF ANSI 372 _________________________________________________ Additional testing and verification for UV dose performed by independ...

Page 4: ...y safe technique that is not known to form any harmful disinfection by products Fig 1 B SAFETY GUIDELINES Lamp contains mercury Hg Dispose or recycle in accordance with applicable laws For information on safe handling procedures and safe disposal and recycling consult Contains mercury Hg Diverting Mercury Management of Lamps Containing Mercury Indicates a hazardous situation which if not avoided w...

Page 5: ...UV LAMP MUST BE REPLACED ANNUALLY After 1 year of use it will no longer provide effective disinfection even though it stays lit WARNING USE ONLY GENUINE AQUA FLO AQUV LAMPS Use of non Aqua Flo AQUV UV lamps can result in unsafe drinking water which may lead to illness and or death ballast failure or fire and will void your product warranty see page 12 for details Canature WaterGroup U S A Inc Cana...

Page 6: ...he AQUV 20 AQUV 12 systems have been designed for maximum water flow rates of 20 US GPM 70 liters per minute and 12 US GPM 45 liters per minute respectively If higher flow rates exist occasionally it is recommended that a flow restricter be installed at the inlet port 12 US GPM for AQUV 20 and 12 US GPM for AQUV 12 The system should be installed indoors in a protected area where the temperature do...

Page 7: ...pipes divide into hot and cold Fig 2 Water Meter OR UV System Water Heater Cold water to house Hot water to house CityWater WellWater Water Softener Optional PressureTank WellWater Water Flow OR Water Flow Water Flow Water Flow Fig 2 Fig 3 Fittings Required for Installation Not Included Fittings required for a typical install on 3 4 copper pipe are 3 4 FNPT female adapters 3 4 Tee 3 4 Elbows 3 4 c...

Page 8: ... the filter cartridges Reinsert the new cartridge into the sump and screw the sump back onto the filter Hand tighten only 4 Carefully unpack UV lamp and quartz dome Two o rings come with the quartz dome The thinner o ring is installed in the groove of the gland nut 5 Gently slide the dome O ring thicker over the top open end of the quartz dome to about 1 from the open end Fig 4 6 Gently insert the...

Page 9: ... the plastic making it easy to hook up lamp then white plastic part has a little screw to secure it to the gland nut 11 Remove the nut from the ground stud at the top of the unit Next place the ground wire green wire with yellow stripes over the stud and tighten the nut 12 Connect the ballast power cable to the AC supply with surge protector The green lamp on LED will light up and the display will...

Page 10: ...y and thoroughly flush all outlets until the chlorine smell is minimal 7 You are ready to use the water now F BALLAST FOR AQUV UV SYSTEMS Aqua Flo AQUV advanced micro processor controlled electronic UV ballast is for use with Aqua Flo AQUV 8 AQUV12 AQUV 20 Systems It features both audio and visual alarm indicators to indicate the lamp operation and an integral annual lamp change reminder timer NOR...

Page 11: ...ard old cartridge and rinse sump 4 Remove O rings and replace if they have been in use for a year Otherwise wipe them with a soft cloth or paper towel and clean the groove on which the O rings are seated 5 Apply food grade silicone lube on the O rings and replace 6 Clean inside of the head as well to make sure the sealing surface is free of debris and stains 7 Insert new cartridge into the sump an...

Page 12: ...econd beep This will re set the lamp change timer to zero and the 3 second beep will confirm that the re set was successful Winterizing Your System To winterize the system unplug the unit first Drain the pre filter by removing the sump and dump the wate then drain the UV chamber of all water Let the filter cartridge dry out and then reinstall in the housing To drain the UV undo the SS flex connect...

Page 13: ...mber Mounting SS Nut 1 8 36003038 Quartz Dome for AQUV 12 1 9 36003039 Quartz Dome for AQUV 20 1 10 80127302 Dome O Ring Thicker 1 2 for AQUV 20 11 80127301 Gland Nut O Ring Thinner inside nut 1 2 for AQUV 20 12 89113 UV Lamp for AQUV 12 1 13 89114 UV Lamp for AQUV 20 1 14 80127402 Lamp Spring 1 15 36112 Pre filter head 2 20 Sump for pre filter 2 Pressure vent button 2 BH Mounting screw 8 BH mount...

Page 14: ......

Page 15: ......

Page 16: ...y including any warranty of merchantability or fitness for a particular purpose and excludes all other express or implied warranties to the extent permitted by law For clarity where exclusion is not permitted by law those express or implied warranties are not excluded by this warranty This warranty is subject to the following conditions and limitations 1 This warranty will not apply if water passi...

Reviews: