AQUV-12R22 AQUV-20R22

Maximum flow rate @ 30 mJ/cm

2

*

12 gpm / 45 lpm 20 gpm / 75 lpm

Maximum flow rate @ 40 mJ/cm

2

*

8 gpm / 30 lpm 12 gpm / 45 lpm

Lamp service life

9000 Hours

Lamp Power

45 watt

65 watt

Power Consumption

45 watt

65 watt

Annual lamp change timer

Yes

Lamp-ON Indicator

Yes

Audio/Visual alarms

Yes

Reactor chamber material

304 Stainless Steel

Chamber dimensions (D x L)

3.5” x 20.0”

3.5” x ” 31.125”

Controller dimensions (L x D x W)

8” x 3” x 2.25”

Inlet/Outlet port size

3/4”NPT

1” NPT

AC supply voltage

120V, 50/60Hz, 0.8A

Maximum operating pressure

100 psi

Water temperature range

2 - 40°C (36-104°F)

Shipping Weight

47.5lb / 21.5kg

52lbs / 23.6kg

Item as 

Labelled

PART NUM-

BER

DESCRIPTION

QTY

1

40020068

Ballast, power cord & lamp connector assembly

1

2

80126734

Ballast mounting bolts

2

3

80126718

Ballast mounting nuts

2

4

430336

SS UV Chamber for AQUV-12

1

5

430337

SS UV Chamber for AQUV-20

1

6

With Chamber

Gland Nut

1

7

89587

Chamber Mounting SS Nut

1

8

36003038

Quartz Dome for AQUV-12

1

9

36003039

Quartz Dome for AQUV-20

1

10

80127302

Dome O-Ring (Thicker)

1 (2 for AQUV-20)

11

80127301

Gland Nut O-Ring (Thinner) – inside nut

1 (2 for AQUV-20)

12

89113

UV Lamp for AQUV-12

1

13

89114

UV Lamp for AQUV-20

1

14

80127402

Lamp Spring

1

15

36112

Pre-filter head

2

20" Sump for pre-filter

2

Pressure vent button

2

BH Mounting screw

8

BH mounting washer

8

Wrench to open pre-filter housing

1

16

36287

20" 5 micron sediment cartridge

1

17

36288

20" 20 micron sediment cartridge

1

18

60010559

Sump O-rings

4

19

80036768

1”x3/4” reducer bushing

1

20

80036770

¾” street elbow

2

21

80030391

¾” Close Nipple

1

22

33611006

1"x2" Nipple

1

23

80127829

¾” x ¾” Flex Tube, 24”

1

24

89589

UV Bracket - Dual Sump

1

Replacement Parts

System

AQUV-12R22 AQUV-20R22

Item #

40030108

40030110

Lamp

89113

89114

Quartz Dome

36003038

36003039

Controller

40020068

40020068

5 Micron Sediment Cartridge 20”

36287

36287

20 Micron Sediment Cartridge 20”

36288

36288

14

4 5

6

7

1

10

8 9

11

12 13

19

20

21

22

23

24

15

15

15

15

15

15

17

16

18

15

2 3

(I) TECHNICAL SPECIFICATIONS

(J) PARTS LIST

 *Dosage based on a UVT value of 96%

Summary of Contents for AQUV AQUV-12R22

Page 1: ...installed in accordance with local plumbing codes 3 Test the water periodically to verify that the system is performing satisfactorily 4 Discard small parts remaining after the installation 5 Failure to install the system correctly voids the warranty 6 Handle all components of the system with care Do not drop drag or turn components upside down 7 Save these instructions and keep track of your prod...

Page 2: ......

Page 3: ...rganisms present in the water supply Simple maintenance continuous disinfection and ultimately safe water AQUA FLO makes it that easy Tested and Certified by CSA Group to CSA Standard B483 1 to NSF ANSI Standard 61 for material and structural requirements only and to NSF ANSI 372 _________________________________________________ Additional testing and verification for UV dose performed by independ...

Page 4: ...y safe technique that is not known to form any harmful disinfection by products Fig 1 B SAFETY GUIDELINES Lamp contains mercury Hg Dispose or recycle in accordance with applicable laws For information on safe handling procedures and safe disposal and recycling consult Contains mercury Hg Diverting Mercury Management of Lamps Containing Mercury Indicates a hazardous situation which if not avoided w...

Page 5: ...UV LAMP MUST BE REPLACED ANNUALLY After 1 year of use it will no longer provide effective disinfection even though it stays lit WARNING USE ONLY GENUINE AQUA FLO AQUV LAMPS Use of non Aqua Flo AQUV UV lamps can result in unsafe drinking water which may lead to illness and or death ballast failure or fire and will void your product warranty see page 12 for details Canature WaterGroup U S A Inc Cana...

Page 6: ...he AQUV 20 AQUV 12 systems have been designed for maximum water flow rates of 20 US GPM 70 liters per minute and 12 US GPM 45 liters per minute respectively If higher flow rates exist occasionally it is recommended that a flow restricter be installed at the inlet port 12 US GPM for AQUV 20 and 12 US GPM for AQUV 12 The system should be installed indoors in a protected area where the temperature do...

Page 7: ...pipes divide into hot and cold Fig 2 Water Meter OR UV System Water Heater Cold water to house Hot water to house CityWater WellWater Water Softener Optional PressureTank WellWater Water Flow OR Water Flow Water Flow Water Flow Fig 2 Fig 3 Fittings Required for Installation Not Included Fittings required for a typical install on 3 4 copper pipe are 3 4 FNPT female adapters 3 4 Tee 3 4 Elbows 3 4 c...

Page 8: ... the filter cartridges Reinsert the new cartridge into the sump and screw the sump back onto the filter Hand tighten only 4 Carefully unpack UV lamp and quartz dome Two o rings come with the quartz dome The thinner o ring is installed in the groove of the gland nut 5 Gently slide the dome O ring thicker over the top open end of the quartz dome to about 1 from the open end Fig 4 6 Gently insert the...

Page 9: ... the plastic making it easy to hook up lamp then white plastic part has a little screw to secure it to the gland nut 11 Remove the nut from the ground stud at the top of the unit Next place the ground wire green wire with yellow stripes over the stud and tighten the nut 12 Connect the ballast power cable to the AC supply with surge protector The green lamp on LED will light up and the display will...

Page 10: ...y and thoroughly flush all outlets until the chlorine smell is minimal 7 You are ready to use the water now F BALLAST FOR AQUV UV SYSTEMS Aqua Flo AQUV advanced micro processor controlled electronic UV ballast is for use with Aqua Flo AQUV 8 AQUV12 AQUV 20 Systems It features both audio and visual alarm indicators to indicate the lamp operation and an integral annual lamp change reminder timer NOR...

Page 11: ...ard old cartridge and rinse sump 4 Remove O rings and replace if they have been in use for a year Otherwise wipe them with a soft cloth or paper towel and clean the groove on which the O rings are seated 5 Apply food grade silicone lube on the O rings and replace 6 Clean inside of the head as well to make sure the sealing surface is free of debris and stains 7 Insert new cartridge into the sump an...

Page 12: ...econd beep This will re set the lamp change timer to zero and the 3 second beep will confirm that the re set was successful Winterizing Your System To winterize the system unplug the unit first Drain the pre filter by removing the sump and dump the wate then drain the UV chamber of all water Let the filter cartridge dry out and then reinstall in the housing To drain the UV undo the SS flex connect...

Page 13: ...mber Mounting SS Nut 1 8 36003038 Quartz Dome for AQUV 12 1 9 36003039 Quartz Dome for AQUV 20 1 10 80127302 Dome O Ring Thicker 1 2 for AQUV 20 11 80127301 Gland Nut O Ring Thinner inside nut 1 2 for AQUV 20 12 89113 UV Lamp for AQUV 12 1 13 89114 UV Lamp for AQUV 20 1 14 80127402 Lamp Spring 1 15 36112 Pre filter head 2 20 Sump for pre filter 2 Pressure vent button 2 BH Mounting screw 8 BH mount...

Page 14: ......

Page 15: ......

Page 16: ...y including any warranty of merchantability or fitness for a particular purpose and excludes all other express or implied warranties to the extent permitted by law For clarity where exclusion is not permitted by law those express or implied warranties are not excluded by this warranty This warranty is subject to the following conditions and limitations 1 This warranty will not apply if water passi...

Reviews: