INSTALLATION & OPERATING INSTRUCTIONS 

 

GENERAL 

Your AQUA-FLO pump has been quality built and engineered to give maximum 
efficiency under normal water pumping conditions.  Consult the manufacturer for 
any other applications. 

LOCATION OF PUMP 

For best pump performance, locate the system as close to the water source as 
possible.  Provide adequate access around the pump for inspection and 
maintenance.  Place pump on a firm level surface.  Pump need not be bolted 
down unless required by local code. 

PUMP CONNECTIONS 

Suction line from pool (skimmer and main drain) must be connected to inlet at 
hair and lint trap.  Discharge line to pool (return lines) must be connected to 
outlet at top of pump via filter.  If pump is installed below water level of pool, 
install valves on the inlet and outlet piping to permit removing of equipment 
without draining the pool. 

CAUTION

:  During the pressure test procedure, this pump is under pressure.  

DO NOT LOOSEN lock handles while pump is running or until all pressure is 
released.  Tighten lock handles securely by hand only.  Raise pressure slowly.  
Do not exceed 50 psi.  Extreme care must be taken during pressure test.  Failure 
to follow these instructions explicitly can result in personal injury. 

PRIMING PUMP 

At initial start-up, pump must be primed by filling hair and lint trap with water.  To 
prime pump, remove cover from hair and lint trap: fill pump and suction trap with 
water.  Replace cover (make sure the o-ring is in place) and tighten lock handles. 
Pump will now prime, with priming time depending upon lift and horizontal 
distance of suction piping. 

CAUTION:

 Do not remove hair and lint strainer lid while pump is running or 

under pressure!  Lid is held in place by lock handles which can be removed or 
tightened by hand.  Basket must be kept clear of leaves and debris at all times. 

REMOVING BASKET 

1.)  Turn off motor.  2.) Remove lid.  3.) Remove basket and empty debris.  4.) 

Replace basket, fill with water, replace lid securely to prevent air from 
entering and tighten.  DO NOT USE TOOLS.  5.) Turn on motor.  6.)  Open 
air-relief valve on top of filter until steady stream of water comes out. 

 

NOTE:

  If pump is installed below water level of pool, close return and suction 

lines prior to opening hair and lint pot.  Make sure to re-open valves prior to 
operating. 

DO NOT RUN PUMP DRY! 

Always maintain proper water level in pool.  If water level falls below skimmer 
intake, pump will suck air.  Pump is equipped with a maintenance-free, heavy-
duty mechanical seal.  Damage will occur if pump runs dry, and warranty will be 
voided. 

TO PREVENT FREEZING 

Drain liquid from pump through plug at bottom section of volute.  It is 
recommended to apply a good rust inhibitor into liquid end to prevent corrosion.  

Summary of Contents for "A" Series & "LEA" Series Pumps A Series

Page 1: ...rmanently installed pools and may also be used with hot tubs and spas if so marked Do not use with storable pools A permanently installed pool is constructed in or on the ground or in a building such that it cannot be readily disassembled for storage A storable pool is constructed so that it may be readily disassembled for storage and reassembled to its original integrity and has a maximum dimensi...

Page 2: ...t up pump must be primed by filling hair and lint trap with water To prime pump remove cover from hair and lint trap fill pump and suction trap with water Replace cover make sure the o ring is in place and tighten lock handles Pump will now prime with priming time depending upon lift and horizontal distance of suction piping CAUTION Do not remove hair and lint strainer lid while pump is running or...

Page 3: ... elements 7 Locate motor on a slight elevation so water will drain away from motor 8 Avoid spilling or dripping liquid chemical on or near motor 9 Avoid splashing water or hosing deck near motor Water damage voids warranty For replacements contact your local supplier or authorized service center WARNING All electrical wiring of the motor installation must be done by a qualified electrician in acco...

Page 4: ...ce of volute Not pumping water check Worn or damaged impeller Circuit breakers Incorrect or loose wire connections Motor does not run check Thermal protector in motor tripped Allow motor to cool then try to restart Make sure motor shaft turns free Jammed impeller or an obstruction in volute casing Motor makes humming noise but won t start check Low voltage and undersized wire Incorrect or loose wi...

Page 5: ...ft keyway Align pump bracket holes with threaded holes on motor and install four 3 8 16 hexbolts and tighten with 9 16 wrench STEP 4 Place assembled pump in its normal position on the pump base To adjust impeller place screwdriver on the pump shaft as shown and gently pry pump shaft towards motor 015 inches and tighten one set screw with 1 8 Allen wrench Rotate shaft to check if impeller is clear ...

Page 6: ...ge Less Foot 10 10 92770150 92770150 Volute 3 0 HP Volute 3 0 HP 10A 10A 92770200 92770200 Volute 33 2 0 HP 100 Drain 11 11 91100100 91100100 Base Plastic Base Plastic 12 12 99050110 99050110 Bolt Hex Machine 5 16 18 x 1 Bolt Hex Machine 5 16 18 x 1 13 13 99890050 99890050 Washer Lock 5 16 Washer Lock 5 16 14 14 92290000 92290000 Plug Pipe Plug Pipe 15 15 91500150 91500150 Gasket Trap 5 Gasket Tra...

Page 7: ...DIAGRAM Please Refer to table located on page 6 AQUA FLO LLC P O BOX 2526 CHINO CALIFORNIA 91708 SHIPPING 5651 SCHAEFER AVENUE CHINO CALIFORNIA 91710 TEL 909 591 7453 FAX 909 627 5660 WWW AQUA FLO COM 7 ...

Page 8: ...ee through five any such products shall prove defective the original retail purchaser shall be entitled to purchase replacement equipment or components at the following percentage off the current published list price Third year 60 Fourth year 40 Fifth year 20 1 This warranty shall not apply to any failures resulting from negligence abuse misuse misapplication improper installation alteration or mo...

Reviews: