LEAKSHIELD
●
Read this manual thoroughly and entirely!
●
Save your data onto suitable media before working on your hardware!
●
This product is not designed for use in life support appliances, devices, or
systems where malfunction of this product can reasonably be expected to re-
sult in personal injury. Aqua Computer GmbH & Co. KG customers using or
selling this product for use in such application do so at their own risk and
agree to fully indemnify Aqua Computer GmbH & Co. KG for any damages
resulting from such application!
●
Never touch the membrane on the bottom side of LEAKSHIELD. Damage to
the membrane can cause moisture to enter LEAKSHIELD and subsequently
cause the unit to fail. If you notice any damage to the membrane, contact
the Aqua Computer Technical Support
●
Use only DP Ultra as coolant
4.
4.
4.
4. Requirements for the operation of LEAKSHIELD
Requirements for the operation of LEAKSHIELD
Requirements for the operation of LEAKSHIELD
Requirements for the operation of LEAKSHIELD
In order to operate LEAKSHIELD properly, there are some principles to be ob-
served when selecting the cooling system.
LEAKSHIELD can only be used if the maximum pump pressure in the system is less
ressure in the system is less
ressure in the system is less
ressure in the system is less
than 450 mbar
than 450 mbar
than 450 mbar
than 450 mbar. This is the case for almost all systems with one pump. For systems
with more than one pump, this must be checked accordingly, e. g. by measuring
the pressure.
The second prerequisite is that the tubing is suitable for the required vacuum
tubing is suitable for the required vacuum
tubing is suitable for the required vacuum
tubing is suitable for the required vacuum.
As a broad rule, the outer diameter of PVC tubing should be at least 1.5 times the
inner diameter of soft tubing.
For PUR tubing, a factor of 1.2 is usually sufficient. Hardtubes are generally suit-
able. Without information on compatibility, we recommend testing at slightly in-
creased negative pressure and maximum water temperature before use.
The components of the water cooling system have to be suitable for the operation
with LEAKSHIELD as well and have to withstand the necessary negative pressure
permanently. For Aqua Computer products this applies without exceptions. For
For
For
For
products from other suppliers, you have to check this before starting operation!
products from other suppliers, you have to check this before starting operation!
products from other suppliers, you have to check this before starting operation!
products from other suppliers, you have to check this before starting operation!
It is also important that there is sufficient air volume in the reservoir
sufficient air volume in the reservoir
sufficient air volume in the reservoir
sufficient air volume in the reservoir. For safe oper-
ation, there should be at least 100 ml of air in the reservoir.
To ensure safe operation, only coolants of the DP Ultra series
only coolants of the DP Ultra series
only coolants of the DP Ultra series
only coolants of the DP Ultra series are approved for
use. Even if many other coolants are certainly trouble-free, we cannot guarantee
the function with these coolants.
© 2021
Aqua Computer GmbH & Co. KG
- 5 -
Gelliehäuser Str. 1, 37130 Gleichen
computer
aqua