7

TEMPERATURE SCALE 

With this setting you have the choice of the displayed temperature in Fahrenheit or Celsius. 
Default setting is “F.” 
 

DEFROST SELECTION 

With this setting you can select whether defrosting shall be done in with air flow or by energizing the 
reversing valve. By pressing either up or down you can toggle between “AIR DEFROSTING” or 
“REVERSE CYCLE”. Default setting is “AIR DEFROSTING.”. 
 

WATER SENSOR CALIBRATION 

With this setting you can calibrate the water temperature reading. The calibration range is +/- 10 degrees F 
or +/- 5 degrees Celsius. 
Default setting is “0”. 
 

EVAPORATOR SENSOR CALIBRATION 

With this setting you can calibrate the evaporator temperature reading. The calibration range is+/- 10 
degrees Fahrenheit or +/- 5 degrees Celsius. Default setting is “0”. 
 
 
 

ELECTRONIC CONTROL PANEL 

 

 

 

 

         

 

 

 

 

 
 
 
 
 
 
 
 
 

                                                  
                                                MODE SELECTION 

 
 
NORMAL MODE

 

 

 

When power is applied, the heater will turn on in the last mode in which it was used. 

 

User adjustable temperature range will be 50 to 95 degrees in Pool mode and 50 to 104 
degrees in Spa mode. 

▼ 

▲ 

LCD DISPLAY 

Displays the actual pool/spa 

temperature.  In select mode 

displays other parameters. 

SELECT/SERVICE KEY 

Used to select mode of 
operation and enter service 
mode. 

 INCREASE KEY 

 DECREASE KEY 

                 

POOL – HEAT 

                          85◦ 

Summary of Contents for Vintage Classic Series

Page 1: ...R FLOW CONNECTIONS 2 3 ELECTRICAL CONNECTIONS 4 MODES OF OPERATION 5 WIRING DIAGRAMS 6 ELECTRONIC CONTROL PANEL 7 8 CHEMICAL USE 9 START UP 10 11 MAINTENANCE 12 TROUBLESHOOTING CHECKLIST 12 13 CALLING...

Page 2: ...ion consider the following Heater must be located outdoors Minimum of 24 of clearance on access service side of heater Minimum of 18 of clearance on all three air intake sides of heater Minimum of 48...

Page 3: ...owed run the filter pump and check the entire system for water leaks Make sure filter is clean and there are no obstructions in the filtering system Proper water flow is essential to the performance o...

Page 4: ...the bottom of the electrical enclosure using a weather tight fitting A knockout is provided to accept the weather tight fitting Mounting conduit directly to the electrical enclosure will ensure a moi...

Page 5: ...1 USE COPPER CONDUCTORS ONLY 2 CONNECT FIELD WIRING IN GROUNDED WEATHER TIGHT CONDUIT PER RATING PLATE 3 CONNECT BOND WIRE TO POOL STEEL USING 8 SOLID COPPER WIRE OR LARGER 4 ALL WIRING MUST CONFORM...

Page 6: ...ed the heater will operate in pool mode The default setting is DISABLED REMOTE THERMOSTAT With this setting you may enable or disable the remote capability In the POOL MODE you will have the capabilit...

Page 7: ...ge is 10 degrees F or 5 degrees Celsius Default setting is 0 EVAPORATOR SENSOR CALIBRATION With this setting you can calibrate the evaporator temperature reading The calibration range is 10 degrees Fa...

Page 8: ...stem and to avoid short cycling the compressor During heating once the water temperature reaches the set point compressor is turned off POOL MODE COOLING When operating in pool cool mode the display w...

Page 9: ...ow the set point the control will energize spa heating mode compressor after the time delay has expired During heating once the water temperature reaches the set point the compressor turns off CHEMICA...

Page 10: ...al water temperature and the 5 minute time delay is satisfied the compressor will start NOTE Each time the compressor turns off it is protected by a 5 minute anti cycling delay INITIAL HEATING Initial...

Page 11: ...n Analyzers The heater is equipped with internal devices to monitor and protect the integrity of the unit Should an abnormal condition occur these devices will interrupt the operation of the unit and...

Page 12: ...f the finish Winterizing When the heater is exposed to freezing temperatures it is essential that all water within the unit be properly drained When water freezes it expands damaging piping Turn therm...

Page 13: ...r is dirty or clogged Shortage of water to pump air leak Undersized pump Valves not in correct position Filter in backwash mode Water pressure switch needs adjustment or is defective HIGH REFRIGERANT...

Page 14: ...IES LLC A factory representative will assist you or your serviceman over the phone SERVICE PERFORMED WITHIN THE WARRANTY PERIOD MUST BE APPROVED BY AQUA COMFORT TECHNOLOGIES LLC PRIOR TO SERVICE BEING...

Reviews: