 Qualified personnel should perform installation, maintenance and service. 

 Make sure all field wiring conforms to the heater specifications and all national and local  

   codes. 

 Disconnect all power sources before performing any maintenance or service to the heater. 

 

INSPECTION 

Immediately upon receipt, inspect cartons and their contents for damage due to transit.   
Damage, if found, should be noted on delivery papers and a claim filed with the carrier.  Also, 
check unit data plate to make sure you have the proper model, before installing. 

 
GENERAL INFORMATION 

The information in this manual was prepared to assist in the proper installation, operation,  
maintenance and service of your new heat pump pool heater.  Please read the entire manual  
and follow all instructions.  Improper installation and use can result in damage to the heater, 
unsatisfactory operation, and may void the warranty.  Retain this manual for quick reference. 
 
 
 

INSTALLATION 

 

 

When selecting a location consider the following: 

 Heater must be located outdoors. 

 Minimum of 24” of clearance on access / service side of heater. 

 Minimum of 18” of clearance on all three air intake sides of heater. 

 Minimum of 48” of clearance for air discharge (top of unit). 

 The heater should sit on a solid level surface sufficient above grade to prevent water from  

   entering it, and allowing condensate to drain from base. 

 The length of water piping and electric should be kept to a minimum to avoid capacity loss  

   and decreased efficiency.  
  
 
 

WATER FLOW & CONNECTIONS 

 

 

Water connections are made at the rear of the heater.  Both water in and out are labeled just  
above the water connections.  LEFT REAR = WATER IN and RIGHT REAR = WATER OUT.  
2” unions are supplied and are made to accept 2” rigid PVC pipe.  NOTE:  unions can be used  
for quick drainage of your heater and winterizing. 

 Heater must be piped downstream from filter in the pool return line. 

 

Inline chlorinators must be piped downstream from heater.  A check valve must be 

   installed between the heater and chlorinator to prevent drain back of the chlorine when 
   the pump is off.  A chemical trap may also be piped at least six (6) inches above the 
height of the chlorinator. 

Summary of Contents for AC110

Page 1: ...LOW CONNECTIONS 2 3 ELECTRICAL CONNECTIONS 4 MODES OF OPERATION 5 WIRING DIAGRAMS 6 ELECTRONIC CONTROL PANEL 7 CHEMICAL USE 8 START UP 9 10 MAINTENANCE 10 11 TROUBLESHOOTING CHECKLIST 11 12 CALLING FOR SERVICE 12 WARRANTY 13 WARRANTY REGISTRATION 14 SAFETY CONSIDERATIONS Proudly Made in the USA support aquacomfort com www aquacomfort com service and support 888 475 7443 ALL IN GROUND MODELS INSTAL...

Page 2: ...the following Heater must be located outdoors Minimum of 24 of clearance on access service side of heater Minimum of 18 of clearance on all three air intake sides of heater Minimum of 48 of clearance for air discharge top of unit The heater should sit on a solid level surface sufficient above grade to prevent water from entering it and allowing condensate to drain from base The length of water pip...

Page 3: ...lowed run the filter pump and check the entire system for water leaks Make sure filter is clean and there are no obstructions in the filtering system Proper water flow is essential to the performance of your heater The minimum flow rate is 20 GPM TYPICAL WATER FLOW CONNECTIONS ...

Page 4: ... on left side of hinged electrical enclosure 3 Route weather tight flexible conduit through opening at base of unit Connect conduit to the bottom of the electrical enclosure using a weather tight fitting A knockout is provided next to the main contactor to accept a weather tight fitting Mounting conduit directly to the electrical enclosure will ensure a moisture tight seal extending the life of th...

Page 5: ...o turn the heater on and off a normally open dry contact can be made at terminals 18 and 19 on the bottom right of the electronic control board The red jumper at the top of the control board must then be cut to activate this system In the case of a remote thermostat where the temperature will be regulated externally set the Pool Mode to the OFF position and the Spa Mode to 104 F 40 C The heater wi...

Page 6: ...6 ...

Page 7: ...econds then revert back to the actual pool or spa water temperature Selecting Pool or Spa Mode Press the SELECT KEY until you reach P_S Pressing the UP or DOWN key will allow you to enter either POOL or SPA mode Green LED indicator lights will verify the mode selected FIL MODE MUST BE IN THE OFF POSITION OR A FLO3 ERROR CODE WILL BE DISPLAYED Selecting temperature in Fahrenheit or Celsius The fact...

Page 8: ...c chlorinators must be piped downstream from the heater A check valve must be installed between the chlorinator and heater to prevent raw chlorine from draining back into the heater A chemical trap may be piped at least six 6 inches above the chlorinator See piping diagram B Always maintain the following water quality requirements PH LEVEL 7 4 to 7 8 CHLORINE CONCENTRATION 1 to 5 PPM TOTAL ALKALIN...

Page 9: ...may require you to run your heater and filter pump continuously for at least 24 hours or more depending on the following factors Temperature difference between actual water temperature and desired water temperature Size of pool Ambient air temperature the cooler the air temperature the longer the heating time Heat loss evaporative convective radiative and conductive A pool cover solar blanket may ...

Page 10: ...water pressure switch will shut down the unit When normal water flow resumes the heater will automatically restart itself Other analyzer codes include FL3 LP3 LP dPO PO dPC Pc PLE CSE and SPi The TROUBLESHOOTING CHECKLIST on page 11 goes into further detail on these analyzer codes MAINTENANCE WARNING DISCONNECT ELECTRICAL POWER TO UNIT BEFORE STARTING ANY MAINTENANCE TO PREVENT SERIOUS INJURY FROM...

Page 11: ...re are no restrictions to its airflow Certain ambient air conditions may cause the heater to go into defrost mode displayed on the control panel as FS NOTE IT IS NORMAL FOR WATER TO DRIP FROM THE DRAINHOLES AT THE BASE OF THE HEATER THE UNIT PRODUCES CONDENSATE WHEN IT OPERATES Analyzer Codes FAILURE LOCK OUT This feature is for the protection of the heater If the same failure occurs three 3 times...

Page 12: ...l the error message disappears The control will be reinitiated to factory default Re enter the setpoints SPi Defective controller remove power and restart If error is still present replace controller CALLING FOR SERVICE Please eliminate any water flow problems before calling for service If you are unable to contact the installing agent please go to www aquacomfort com service and support to contac...

Reviews: