- 22 -
5800 SERIES LOOP NUMBERS
LOOP 1
5806/5807/5808/5808LST
ENROLL AS "RF"
LOOP 1
5809
ENROLL AS "RF"
5 8 1 8
ENROLL AS "RF"
LOOP 1
LOOP 1
5814
ENROLL AS "RF"
09012-013-V0
5828/5828V
PROGRAM
HOUSE ID
LOOP 1
(MOTION)
5 8 9 0 / 5 8 9 0 P I
ENROLL AS "RF"
LOOP
1
5 8 0 2 M N
ENROLL AS
"UR" OR "RF"
5 8 0 4 B D / 5 8 0 4 B DV
ENROLL AS "BR"
PROGRAM HOUSE ID
LOOP 4
YOU MUST
ENROLL
THIS BUTTON
LOOP 3
LOOP 1
LOOP 2
•
•
••
•
•
••
•
•
•
• •
• •
•
•••
5804/5804E
ENROLL AS "BR"
LOOP 1
LOOP 2
LOOP 4
YOU MUST
ENROLL
THIS
BUTTON
OFF
LOOP 3
ON
5 8 1 6 T E M P
ENROLL AS "RF"
LOOP 1
(TEMP
SENSOR)
5 8 1 7
ENROLL AS "RF"
LOOP 2
(AUX.
CENTER)
LOOP 1
(PRIMARY)
LOOP 3
(AUX.
RIGHT)
5 8 1 6
ENROLL AS "RF"
LOOP 1
(TERMINALS)
LOOP 2
(REED)
5 8 1 6 M N
ENROLL AS "RF"
LOOP 1
(TERMINALS)
ALTERNATE
POSITION
FOR LOOP 2
LOOP 2
(REED)
LOOP 3
(TERMINALS)
5 8 1 9 S ( W H S & B R S )
ENROLL AS "RF"
LOOP 1
(INTERNAL
SHOCK
SENSOR
LOOP 2
(REED)
5 8 1 9
ENROLL AS "RF"
LOOP 2
(REED)
LOOP 3
(TERMINALS)
LOOP 1
(TERMINALS)
5 8 0 0 WAV E
P RO G R A M
H O U S E I D
5 8 0 0 C O
E N RO L L A S " R F "
5 8 0 0 R L
S E T
H O U S E I D
5 8 0 1
ENROLL AS
"UR" OR "RF"
LOOP 3
LOOP 1
LOOP 2
LOOP 4
YOU MUST
ENROLL
THIS
BUTTON
5 8 4 9
ENROLL AS "RF"
LOOP 1
(SOUND)
5 8 0 2 M N 2
ENROLL AS
"UR" OR "RF"
LOOP
1
LOOP
1
5 8 5 0 ( G B D )
ENROLL AS "RF"
(Gree
n)
(Re
d)
(Y
ello
w)
ARMED
REA
DY
MESSAGE
MIC
Notes:
(1)
You must enroll loop 4 on the 5801, 5804/5804E, and 5804BD/5804BDV transmitters, regardless of whether it is used or
not.
(2) 5804E encrypted (High-Security) devices must be activated while the system is in Go/No Go Test Mode. Refer to
the transmitter’s installation instructions for complete details. The system will confirm enrollment of the encrypted
device by beeping two times.
UL
The 5800CO, 5800RL, 5802MN, 5802MN2, 5804, 5804BD, 5804BDV, 5804E, 5808LST, 5814, 5816TEMP,
5819, 5819S(WHS & BRS), 5828/5828V and 5850(GBD) transmitters are not intended for any UL
installations.
SPECIAL MESSAGES
EE
= Data Entry Error (invalid field number entered while programming; re-enter valid field number).
FC
= Communication Failure
EA
= Exit Alarm
CA
= Cancel Alarm
CC
= Modem Communication (system is in communication with the central station)
dI
= Displayed approximately 4 seconds after powering up. This will revert to the Real-time Clock in approximately 1 minute
and the green “READY” LED should light. To bypass this delay, press: [#] + [0]. If “
dI
” remains displayed for more
than one minute the system is disabled.
PC
= Remote phone control feature is active
PH =
Speaker phone mode feature is active
90
= RF Jam
bF
= Backup LRR/GSM/IP module communication failure (displayed on RF Keypad only)