Service Mode:
The Service Mode accesses
USER RANGE
and
FACTORY
DEFAULTS
.
NOTE:
If factory defaults are reset, the control will
retain the°C or °F selection, i.e. If a customer is operating in °C, a
reset will remain in °C.
Press and hold the “UP” & “DOWN” keys for 10s until the
control beeps, then press the ‘TIME’, ‘TEMP’, ‘TIME’ key within
3 seconds.
HEAT
HEAT
HOLD
HOLD
Service Entry - Hot Dog
1. Use the
UP/DOWN
keys to move among steps; the top display will describe the variable
parameter, the bottom display describes the parameter value.
2. Use the
ZONE 1
key to select the desired parameter.
3. Use the
UP/DOWN
keys to change the parameter value
4. Use the
ZONE 1
key to accept.
To exit, advance to the final step and press the ZONE 1 key.
SERVICE MODE OPERATION
General Specifications:
Beeps:
There are 4 different types of beeps:
1. Key Beep - 0.1 seconds on, for valid key presses
2. Invalid key beep - 3 x (0.1 seconds on, 0.1 seconds off)
3. End of cycle - 3 x (1 second on, 1 second off)
4. Reminder beep - 3 x (1 second on, 1 second off)
HEAT
HEAT
HOLD
HOLD
2
1
COOK
RANGE
LOW
HEAT
HEAT
HOLD
HOLD
2
1
COOK
RANGE
HIGH
HEAT
HEAT
HOLD
HOLD
2
1
HOLD
RANGE
LOW
HEAT
HEAT
HOLD
HOLD
2
1
HOLD
RANGE
HIGH
HEAT
HEAT
HOLD
HOLD
2
1
BUN
RANGE
HIGH
HEAT
HEAT
HOLD
HOLD
2
1
BUN
RANGE
LOW
HEAT
HEAT
HOLD
HOLD
2
1
RESET
FACTORY
DEFAULTS
HEAT
HEAT
HOLD
HOLD
2
1
EXIT
SERVICE
TOGGLE
WITH
ARROWS
12
Summary of Contents for HR-