![APW Wyott FDB-24 Installation And Operating Instructions Manual Download Page 9](http://html1.mh-extra.com/html/apw-wyott/fdb-24/fdb-24_installation-and-operating-instructions-manual_2957327009.webp)
1
2
3
4
5
6
LIGHT-SW
FRONT-SW
BACK-SW
1
2
3
4
5
6
1
2
3
4
5
6
36,42,48,54 MODELS
TWO LAMPHOLDERS
ONE LAMPHOLDER
18,24,30 MODELS
60,66,72 MODELS
THREE LAMPHOLDERS
F-T'STAT
B-T'STAT
ELEMENT
ELEMENT
GR
N
L1
LN
4
3
2
1
5
7
9
10
8
11
13
14
15
15
15
15
A-L1
A-LN
B-L1
C-L1
FOR REMOTE MODELS
LABEL LEAD WIRES AS SHOWN.
LEADS TO BE 6" FROM HOUSING
FDDLB-120V
WIRE #'S 6 AND 12 TO BE 10 GA. - 450°C.
WIRE # 1 TO BE 12 GA. - 100°C.
ALL OTHER WIRES TO BE 12 GA. - 250°C.
3
7
8
6
12
16
17
18
16
1
2
3
4
5
6
FRONT-SW
BACK-SW
1
2
3
4
5
6
F-T'STAT
B-T'STAT
ELEMENT
ELEMENT
GR
N
L1
L2
4
3
2
1
5
6
7
8
9
10
13
12
11
A-L1
A-L2
B-L1
B-L2
FOR REMOTE MODELS
LABEL LEAD WIRES AS SHOWN.
LEADS TO BE 6" FROM HOUSING
FDDB-208/240V
WIRE #'S 6 AND 12 TO BE 10 GA. - 450°C.
WIRE # 1 TO BE 12 GA. - 100°C.
ALL OTHER WIRES TO BE 12 GA. - 250°C.
FDDB-208/240V WIRING DIAGRAM
FDDLB-120V WIRING DIAGRAM
9
G.
H.