APW Wyott FDB-24 Installation And Operating Instructions Manual Download Page 12

ITEM

P/N

DESCRIPTION

QUAN ITEM

P/N

DESCRIPTION

QUAN

FDB / FDLB / FDDB / FDDLB-18 to 72 PARTS LIST

V=QTY VARIES PER UNIT S=SINGLE UNIT OR FDB/FDLB SL=SINGLE LIGHTED UNIT OR FDLB D=DOUBLE UNIT OR FDDB/FDDLB

1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1

2
3
3
3
3
3
3
3
3
3
3
4
5
6
7
8

9
9

10
11

70476835
70476836
70476837
70476838
70476839
70476840
70476841
70476842
70476843
70476844
70476845
70476846
70476847
70476848
70476849
70476850
70476851
70476852
70476853
70476854
70476855
70476856
70476857
70476858
70476859
70476860
70476861
70476862
70476863
70476864

70402028

76211
76212
76213
76214
76215
76216
76217
76218
76219
76220
75917
75916
46877
76159

70400153

70400146
70400147
70400152

76805

HOUSING W/ASS'Y FDB-18
HOUSING W/ASS'Y FDB-24
HOUSING W/ASS'Y FDB-30
HOUSING W/ASS'Y FDB-36
HOUSING W/ASS'Y FDB-42
HOUSING W/ASS'Y FDB-48
HOUSING W/ASS'Y FDB-54
HOUSING W/ASS'Y FDB-60
HOUSING W/ASS'Y FDB-66
HOUSING W/ASS'Y FDB-72
HOUSING W/ASS'Y FDLB-18
HOUSING W/ASS'Y FDLB-24
HOUSING W/ASS'Y FDLB-30
HOUSING W/ASS'Y FDLB-36
HOUSING W/ASS'Y FDLB-42
HOUSING W/ASS'Y FDLB-48
HOUSING W/ASS'Y FDLB-54
HOUSING W/ASS'Y FDLB-60
HOUSING W/ASS'Y FDLB-66
HOUSING W/ASS'Y FDLB-72
HOUSING W/ASS'Y

FDDB/FDDLB-18

HOUSING W/ASS'Y

FDDB/FDDLB-24

HOUSING W/ASS'Y

FDDB/FDDLB-30

HOUSING W/ASS'Y

FDDB/FDDLB-36

HOUSING W/ASS'Y

FDDB/FDDLB-42

HOUSING W/ASS'Y

FDDB/FDDLB-48

HOUSING W/ASS'Y

FDDB/FDDLB-54

HOUSING W/ASS'Y

FDDB/FDDLB-60

HOUSING W/ASS'Y

FDDB/FDDLB-66

HOUSING W/ASS'Y

FDDB/FDDLB-72

INSULATION

OVRHEAD WRM’R 18-72

LIGHT SUPPORT W/A DL-18
LIGHT SUPPORT W/A DL-24
LIGHT SUPPORT W/A DL-30
LIGHT SUPPORT W/A DL-36
LIGHT SUPPORT W/A DL-42
LIGHT SUPPORT W/A DL-48
LIGHT SUPPORT W/A DL-54
LIGHT SUPPORT W/A DL-60
LIGHT SUPPORT W/A DL-66
LIGHT SUPPORT W/A DL-72
LAMPHOLDER TWIN

660W/250V

LAMP 40W COATED

#40A15 120V

NIPPLE, 1/8-27 X 3/4 PLATED
COVER, END DL RH CONTROL
COVER, LARGE FD RH CTRL

INSULATION

OVRHEAD WRM’R 18-72

INSULATION

OVRHEAD WRM’R 18-72

SUPPORT, ELEMENT FD
REFLECTOR FD18

1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1

2
1
1
1
1
1
1
1
1
1
1

V
V
V

1
1

V
V

S-2 D-4
S-1 D-2

11
11
11
11
11
11
11
11
11
12
13
14
15
16
17
18
19
19
19
19
19
19
19
19
19
19
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20

76806
76807
76808
76809
76810
76811
76812
76813
76814

70400154

76803

70402029

76955

70476803
70400151

89184

70400155
70400157
70400159
70400161
70400163
70400165
70400167
70400169
70400171
70400173

75801
75833
75830
75461
75813
75814
75802
75820
75831
75803
75804
75805
75819
75821
75822
75806
75807
75808
75823
75824
75825
75841
75809
75810

REFLECTOR FD24
REFLECTOR FD30
REFLECTOR FD36
REFLECTOR FD42
REFLECTOR FD48
REFLECTOR FD54
REFLECTOR FD60
REFLECTOR FD66
REFLECTOR FD72
COVER, SMALL FD
END PLATE FD
INSULATION

1/2 X 6 X 2-1/2 FD18-72

BRACKET MOUNTING FD
PLATE, FDB AND C END
COVER LARGE FD LH CTRL
BUSHING, .875 HEYCO 2126
EXTRUSION,

BLACK ANODIZED FD-18

EXTRUSION,

BLACK ANODIZED FD-24

EXTRUSION,

BLACK ANODIZED FD-30

EXTRUSION,

BLACK ANODIZED FD-36

EXTRUSION,

BLACK ANODIZED FD-42

EXTRUSION,

BLACK ANODIZED FD-48

EXTRUSION,

BLACK ANODIZED FD-54

EXTRUSION,

BLACK ANODIZED FD-60

EXTRUSION,

BLACK ANODIZED FD-66

EXTRUSION,

BLACK ANODIZED FD-72

ELEMENT, 400W - 120V
ELEMENT, 400W - 208V
ELEMENT, 400W - 240V
ELEMENT, 575W - 120V
ELEMENT, 575W - 208V
ELEMENT, 575W - 240V
ELEMENT, 760W - 120V
ELEMENT, 760W - 208V
ELEMENT, 760W - 240V
ELEMENT, 920W - 120V
ELEMENT, 920W - 208V
ELEMENT, 920W - 240V
ELEMENT, 1100W - 120V
ELEMENT, 1100W - 208V
ELEMENT, 1100W - 240V
ELEMENT, 1265W - 120V
ELEMENT, 1265W - 208V
ELEMENT, 1265W - 240V
ELEMENT, 1425W - 120V
ELEMENT, 1425W - 208V
ELEMENT, 1425W - 240V
ELEMENT, 1610W - 120V
ELEMENT, 1610W - 208V
ELEMENT, 1610W - 240V

S-1 D-2
S-1 D-2
S-1 D-2
S-1 D-2
S-1 D-2
S-1 D-2
S-1 D-2
S-1 D-2
S-1 D-2
S-1 D-2
S-1 D-3
S-2 D-4
S-2 D-4

1

S-0 D-1

S-0 SL-1 D-2

S-1 D-2
S-1 D-2
S-1 D-2
S-1 D-2
S-1 D-2
S-1 D-2
S-1 D-2
S-1 D-2
S-1 D-2
S-1 D-2
S-1 D-2
S-1 D-2
S-1 D-2
S-1 D-2
S-1 D-2
S-1 D-2
S-1 D-2
S-1 D-2
S-1 D-2
S-1 D-2
S-1 D-2
S-1 D-2
S-1 D-2
S-1 D-2
S-1 D-2
S-1 D-2
S-1 D-2
S-1 D-2
S-1 D-2
S-1 D-2
S-1 D-2
S-1 D-2
S-1 D-2
S-1 D-2

12

Get user manuals: 

See SafeManuals.com

 

 

Summary of Contents for FDB-24

Page 1: ...ndable service when used according to the instructions in this manual and standard commercial kitchen practices Initial heating of unit may generate smoke or fumes and must be done in a well ventilate...

Page 2: ...kout and terminal blocks easily accessed through control box access plate For supply connections use minimum no 14 AWG copper wires suitable foratleast90 C 2 SECTION 1 2 3 4 5 6 7 8 9 10 11 ITEM Gener...

Page 3: ...1610 1850 3220 3460 1800 2040 3600 3840 1980 2220 3960 4200 3 3 4 0 6 7 7 3 4 8 5 5 9 6 10 3 6 3 7 0 12 7 13 3 7 7 9 0 15 3 16 7 9 2 10 5 10 5 11 9 11 9 13 2 13 4 15 4 15 0 17 0 1 9 3 8 2 8 5 5 3 7 7...

Page 4: ...FDDLB 66 FDDB FDDLB 72 19 26 19 26 19 26 19 26 19 26 19 26 19 26 19 26 19 26 19 26 FDLB 18 FDLB 24 FDLB 30 FDLB 36 FDLB 42 FDLB 48 FDLB 54 FDLB 60 FDLB 66 FDLB 72 13 255 13 255 13 255 13 255 13 255 1...

Page 5: ...armersforuseovernon combustiblecountertops A Allfoodserviceequipmentshouldbeoperatedbytrainedpersonnel B Donotallowyourcustomerstocomeincontactwithanysurfacelabeled CAUTIONHOT C Switch on unit Place p...

Page 6: ...BE 12 GA 100 C ALL OTHER WIRES TO BE 12 GA 200 OR 250 C 6 7 1 2 3 4 5 6 FRONT SW F T STAT ELEMENT GRN L1 L2 4 3 2 1 5 6 7 A L1 A L2 FOR REMOTE MODELS LABEL LEAD WIRES AS SHOWN LEADS TO BE 6 FROM HOUSI...

Page 7: ...AS SHOWN LEADS TO BE 6 FROM HOUSING 11 7 6 12 3 LIGHT SW FRONT SW 1 2 3 4 5 6 1 2 3 4 5 6 36 42 48 54 MODELS TWO LAMPHOLDERS ONE LAMPHOLDER 18 24 30 MODELS 60 66 72 MODELS THREE LAMPHOLDERS B T STAT E...

Page 8: ...LN A L1 B L1 FOR REMOTE MODELS LABEL LEAD WIRES AS SHOWN LEADS TO BE 6 FROM HOUSING 11 7 6 12 3 13 1 2 3 4 5 6 FRONT SW BACK SW 1 2 3 4 5 6 F T STAT B T STAT ELEMENT ELEMENT GRN L1 LN 4 3 2 1 5 7 8 1...

Page 9: ...FDDLB 120V WIRE S 6 AND 12 TO BE 10 GA 450 C WIRE 1 TO BE 12 GA 100 C ALL OTHER WIRES TO BE 12 GA 250 C 3 7 8 6 12 16 17 18 16 1 2 3 4 5 6 FRONT SW BACK SW 1 2 3 4 5 6 F T STAT B T STAT ELEMENT ELEMEN...

Page 10: ...C ALL OTHER WIRES TO BE 12 GA 250 C 18 1 2 3 4 5 6 LIGHT SW FRONT SW BACK SW 1 2 3 4 5 6 1 2 3 4 5 6 36 42 48 54 MODELS TWO LAMPHOLDERS ONE LAMPHOLDER 18 24 30 MODELS 60 66 72 MODELS THREE LAMPHOLDER...

Page 11: ...DB FDLB FDDB FDDLB 18 to 72 EXPLODED VIEW 17 8 11 2 4 5 7 18 13 16 14 10 1 27 31 26 32 33 23 25 24 29 30 36 35 28 34 15 21 3 9 20 19 22 12 10 PARTS LIST EXPLODED VIEW Get user manuals See SafeManuals...

Page 12: ...RM R 18 72 SUPPORT ELEMENT FD REFLECTOR FD18 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 2 1 1 1 1 1 1 1 1 1 1 V V V 1 1 V V S 2 D 4 S 1 D 2 11 11 11 11 11 11 11 11 11 12 13 14 15 16 1...

Page 13: ...LD ASSY FD 72 REMOTE ENCLOSURE SNGL CNTRL 8 REMOTE ENCLOSURE SNGL CNTRL 12 W ASS Y REMOTE BOX CVR 12 W FUSE W ASS Y REMOTE BOX CVR 12 W FUSE W ASS Y REMOTE BOX CVR 8 2 T B W ASS Y REMOTE BOX CVR 8 1 T...

Page 14: ...llergrills which have in store service The following conditions are not covered by warranty Equipment failure relating to improper installation improper utility connection or supply and problems due t...

Page 15: ...E Please complete this information and retain this manual for the life of the equipment For WarrantyServiceand orParts thisinformationisrequired ModelNumber SerialNumber DatePurchased Notes 15 Get use...

Page 16: ...APW WYOTT 729 Third Avenue Dallas TX 75226 Phone 1 Fax 1 214 565 0976 Toll Free 1 800 527 2100 Website www apwwyott com E mail info apwwyott com 214 421 7366 16 Get user manuals See SafeManuals com...

Reviews: