APW Wyott FDB-24 Installation And Operating Instructions Manual Download Page 10

1
2

3

4
5

6

LIGHT-SW

FRONT-SW

BACK-SW

1
2

3

4
5

6

1
2

3

4
5

6

36,42,48,54 MODELS

TWO LAMPHOLDERS

ONE LAMPHOLDER

18,24,30 MODELS

60,66,72 MODELS

THREE LAMPHOLDERS

F-T'STAT

B-T'STAT

ELEMENT

ELEMENT

GR

N

L1

L2

LN

4

3

2

1

5

6

7

8

9

10

13

12

11

14

15
16

17

17
17

17

A-L1
A-L2

B-L1

B-L2

C-L1

C-LN

FOR REMOTE MODELS

LABEL LEAD WIRES AS SHOWN.

LEADS TO BE 6" FROM HOUSING

FDDLB-208/240V

WIRE #'S 6 AND 12 TO BE 10 GA. - 450°C.

WIRE # 1 TO BE 12 GA. - 100°C.

ALL OTHER WIRES TO BE 12 GA. - 250°C.

18

1
2

3

4
5

6

LIGHT-SW

FRONT-SW

BACK-SW

1
2

3

4
5

6

1
2

3

4
5

6

36,42,48,54 MODELS

TWO LAMPHOLDERS

ONE LAMPHOLDER

18,24,30 MODELS

60,66,72 MODELS

THREE LAMPHOLDERS

F-T'STAT

B-T'STAT

ELEMENT

ELEMENT

L1

L2

LN

4

3

2

1

5

6

7

8

9

10

13

12

11

14

15
16

17

17
17

17

A-L1
A-L2

B-L1

B-L2

C-L1

C-LN

FOR REMOTE MODELS

LABEL LEAD WIRES AS SHOWN.

LEADS TO BE 6" FROM HOUSING

FDDLB-208/240V W/FUSE

WIRE #'S 6 AND 12 TO BE 10 GA. - 450°C.

WIRE # 1 TO BE 12 GA. - 100°C.

ALL OTHER WIRES TO BE 12 GA. - 250°C.

18

19

GR

N

FDDLB-208/240V WIRING DIAGRAM

FDDLB-208/240V w/FUSE WIRING DIAGRAM

10

I.

J.

Get user manuals: 

See SafeManuals.com

 

 

Summary of Contents for FDB-24

Page 1: ...ndable service when used according to the instructions in this manual and standard commercial kitchen practices Initial heating of unit may generate smoke or fumes and must be done in a well ventilate...

Page 2: ...kout and terminal blocks easily accessed through control box access plate For supply connections use minimum no 14 AWG copper wires suitable foratleast90 C 2 SECTION 1 2 3 4 5 6 7 8 9 10 11 ITEM Gener...

Page 3: ...1610 1850 3220 3460 1800 2040 3600 3840 1980 2220 3960 4200 3 3 4 0 6 7 7 3 4 8 5 5 9 6 10 3 6 3 7 0 12 7 13 3 7 7 9 0 15 3 16 7 9 2 10 5 10 5 11 9 11 9 13 2 13 4 15 4 15 0 17 0 1 9 3 8 2 8 5 5 3 7 7...

Page 4: ...FDDLB 66 FDDB FDDLB 72 19 26 19 26 19 26 19 26 19 26 19 26 19 26 19 26 19 26 19 26 FDLB 18 FDLB 24 FDLB 30 FDLB 36 FDLB 42 FDLB 48 FDLB 54 FDLB 60 FDLB 66 FDLB 72 13 255 13 255 13 255 13 255 13 255 1...

Page 5: ...armersforuseovernon combustiblecountertops A Allfoodserviceequipmentshouldbeoperatedbytrainedpersonnel B Donotallowyourcustomerstocomeincontactwithanysurfacelabeled CAUTIONHOT C Switch on unit Place p...

Page 6: ...BE 12 GA 100 C ALL OTHER WIRES TO BE 12 GA 200 OR 250 C 6 7 1 2 3 4 5 6 FRONT SW F T STAT ELEMENT GRN L1 L2 4 3 2 1 5 6 7 A L1 A L2 FOR REMOTE MODELS LABEL LEAD WIRES AS SHOWN LEADS TO BE 6 FROM HOUSI...

Page 7: ...AS SHOWN LEADS TO BE 6 FROM HOUSING 11 7 6 12 3 LIGHT SW FRONT SW 1 2 3 4 5 6 1 2 3 4 5 6 36 42 48 54 MODELS TWO LAMPHOLDERS ONE LAMPHOLDER 18 24 30 MODELS 60 66 72 MODELS THREE LAMPHOLDERS B T STAT E...

Page 8: ...LN A L1 B L1 FOR REMOTE MODELS LABEL LEAD WIRES AS SHOWN LEADS TO BE 6 FROM HOUSING 11 7 6 12 3 13 1 2 3 4 5 6 FRONT SW BACK SW 1 2 3 4 5 6 F T STAT B T STAT ELEMENT ELEMENT GRN L1 LN 4 3 2 1 5 7 8 1...

Page 9: ...FDDLB 120V WIRE S 6 AND 12 TO BE 10 GA 450 C WIRE 1 TO BE 12 GA 100 C ALL OTHER WIRES TO BE 12 GA 250 C 3 7 8 6 12 16 17 18 16 1 2 3 4 5 6 FRONT SW BACK SW 1 2 3 4 5 6 F T STAT B T STAT ELEMENT ELEMEN...

Page 10: ...C ALL OTHER WIRES TO BE 12 GA 250 C 18 1 2 3 4 5 6 LIGHT SW FRONT SW BACK SW 1 2 3 4 5 6 1 2 3 4 5 6 36 42 48 54 MODELS TWO LAMPHOLDERS ONE LAMPHOLDER 18 24 30 MODELS 60 66 72 MODELS THREE LAMPHOLDER...

Page 11: ...DB FDLB FDDB FDDLB 18 to 72 EXPLODED VIEW 17 8 11 2 4 5 7 18 13 16 14 10 1 27 31 26 32 33 23 25 24 29 30 36 35 28 34 15 21 3 9 20 19 22 12 10 PARTS LIST EXPLODED VIEW Get user manuals See SafeManuals...

Page 12: ...RM R 18 72 SUPPORT ELEMENT FD REFLECTOR FD18 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 2 1 1 1 1 1 1 1 1 1 1 V V V 1 1 V V S 2 D 4 S 1 D 2 11 11 11 11 11 11 11 11 11 12 13 14 15 16 1...

Page 13: ...LD ASSY FD 72 REMOTE ENCLOSURE SNGL CNTRL 8 REMOTE ENCLOSURE SNGL CNTRL 12 W ASS Y REMOTE BOX CVR 12 W FUSE W ASS Y REMOTE BOX CVR 12 W FUSE W ASS Y REMOTE BOX CVR 8 2 T B W ASS Y REMOTE BOX CVR 8 1 T...

Page 14: ...llergrills which have in store service The following conditions are not covered by warranty Equipment failure relating to improper installation improper utility connection or supply and problems due t...

Page 15: ...E Please complete this information and retain this manual for the life of the equipment For WarrantyServiceand orParts thisinformationisrequired ModelNumber SerialNumber DatePurchased Notes 15 Get use...

Page 16: ...APW WYOTT 729 Third Avenue Dallas TX 75226 Phone 1 Fax 1 214 565 0976 Toll Free 1 800 527 2100 Website www apwwyott com E mail info apwwyott com 214 421 7366 16 Get user manuals See SafeManuals com...

Reviews: