background image

2

takes pride in the design and quality of our products. When used as intended and with proper

care and maintenance, you will experience years of reliable operation from this equipment. To ensure best

results, it is important that you read and follow the instructions in this manual carefully.

Installation and start-up should be performed by a qualified installer who thoroughly read, understands and

follows these instruction.

If you have questions concerning the installation, operation, maintenance or service of this product, write

Technical Service Department APW/Wyott Foodservice Equipment Company, P.O. Box 1829, Cheyenne,

WY 82003.

Before installing and operating this equipment be sure everyone involved in its operation are fully trained

and are aware of all precautions.Accidents and problems can result by a failure to follow fundamental rules

and precautions.

The following words and symbols, found in this manual, alert you to hazards to the operator, service

personnel or the equipment. The words are defined as follows:

APW Wyott

SAFETY PRECAUTIONS

!

WARNING: This symbol refers to a potential hazard or unsafe practice, which could result in

serious injury or death.

!

!

!

DANGER: This symbol warns of imminent hazard which will result in serious injury or death.

!

!

CAUTION: This symbol refers to a potential hazard or unsafe practice, which may result in minor or

moderate injury or product or property damage.

!

!

NOTICE: This symbol refers to information that needs special attention or must be fully understood

even though not dangerous.

!

CAUTION: These models are designed, built, and sold for commercial use. If these models are

positioned so the general public can use the equipment make sure that cautions, warnings, and

operating instructions are clearly posted near each unit so that anyone using the equipment will

use it correctly and not injure themselvesor harm the equipment.

!

WARNING: Improper installation, adjustment, alteration, service or maintenance can cause

property damage, injury or death. Read the Installation, Operating and Maintenance Instructions

thoroughlybefore installing or servicing this equipment.

!

!

!

WARNING: Check the data plate on this unit before installation. Connect the unit only to the voltage

and frequency listed on the data plate. Connect only to 1 or 3 phase as listed on the data plate.

!

!

!

NOTICE: The unit when installed, must be electrically grounded and comply with local codes, or in

the absence of local codes, with the national electrical code ANSI/NFPA70- latest edition.

Canadian installation must comply with CSA-STANDARD C.22.2 Number 0 M1982 General

Requirements-CanadianElectrical Code Part II, 109-M1981-CommercialCookingAppliances.

!

!

WARNING: Disconnect device from electrical power supply and place a Tag Out-Lockout on the

power plug, indicating that you are working on the circuit.

WARNING: Install per the spacing requirements listed in the installation section of this manual. We

strongly recommend having a competent professional install the equipment.A licensed electrician

should make the electrical connections and connect power to the unit. Local codes should always

be used when connecting these units to electrical power. In the absence of local codes, use the

latest version of the National Electrical Code.

!

!

!

!

CAUTION: Maintenance & repair should be handled by a factory authorized agent. Before doing

any maintenanceor repair, contactAPW Wyott.

Get user manuals: 

See SafeManuals.com

 

 

Summary of Contents for CCW

Page 1: ...itchen practices WARNING Improper installation adjustment alteration service or maintenance can cause property damage injury or death Read the Installation Operating and Maintenance Instructions thoroughly before installing or servicing this equipment R IMPORTANT FOR FUTURE REFERENCE Please complete this information and retain this manual for the life of the equipment For Warranty Service and or P...

Page 2: ...old for commercial use If these models are positioned so the general public can use the equipment make sure that cautions warnings and operating instructions are clearly posted near each unit so that anyone using the equipment will useitcorrectlyandnotinjurethemselvesorharmtheequipment WARNING Improper installation adjustment alteration service or maintenance can cause propertydamage injuryordeath...

Page 3: ...g Maintenance 4 Warranty 8 CAUTION These models are designed built and sold for commercial use If these models are positioned so the general public can use the equipment make sure that cautions warnings and operating instructions are clearly posted near each unit so that anyone using the equipment will useitcorrectlyandnotinjurethemselvesorharmtheequipment WARNING SHOCKHAZARD Donotopenanypanelstha...

Page 4: ... be heated in the original can Be sure to remove the top first If contents of No 1 0 can are not to be completely used in a day the optional stainless container Part No 4359350 is recommended This container will not rust as a commercial can does Putting product directly into the dispenser is not recommended as it might scorch and stick In addition the pump suction tube will be about 1 1 8 short of...

Page 5: ... mating steel parts Wash all parts thoroughly in detergent and a sanitizing solution using the brush provided rinse in hot water and allow the pump to dry Wash seal and O rings separately from metal parts to avoid damage to the soft seal and O ring surfaces a very small nick can cause a large leak Reassemble the pump and lid using the reverse procedure Be sure to replace the spring tang down Sanit...

Page 6: ...pound Quaternary Ammonium Quat Following the manufacturer s label instructions prepare the solution with a minimum concentration of 200 parts per million PPM Do not use chorine based sanitizers because they may damage the plastic parts use iodine based sanitizers because they may discolor the plastic parts and disflavor the product NOTE DO NOT NOTES Get user manuals See SafeManuals com ...

Page 7: ...7 NOTES Get user manuals See SafeManuals com ...

Page 8: ...ergrills which have in store service The following conditions are not covered by warranty Equipment failure relating to improper installation improper utility connection or supply and problems due to ventilation Equipment that has not been properly maintained calibration of controls adjustments damage from improper cleaning and water damage to controls Equipment that has not been used in an approp...

Reviews: