ACTUATORS - RP SERIES
Australian Pipeline Valve - Installation, Operation and Maintenance Manual
3
to +80°C (+176°F)
• High temperature HT actuator with FPM ‘O’ Rings from - 15°C (+5°F) to +150°C (+302°F)
Stroke
There is ±5° adjustable angle at the position of open and end of
close.
Operating Time:
See Technical Data Sheet
Lubrication:
Actuators are factory lubricated for the life under normal operating
conditions.
The standard lubricant is suitable for use from -20°C (-4°C) +80°C
(+176°F)
Construction:
Twin piston rack and pinion actuator design suitable for both indoor and outdoor installation.
Protection and Corrosion Resistance:
Actuators are supplied with corrosion protections for normal environments. For severe duties select from
the protection level table or contact APV.
RESPONSIBILITY FOR VALVE & ACTUATOR APPLICATION
The User is responsible for ordering the correct valves & actuators. The user is responsible for ensuring
APV Valves & Actuators are selected and installed in conformance with the current pressure rating and
design temperature requirements. Prior to installation, the nameplates and drawings should be checked
for proper identification to ensure the valve & actuator is of the proper type, material and is of a suitable
pressure class and temperature rating to satisfy the requirements of the service application.
Note
We recommend that this entire document be read prior to proceeding with any
installation. Do not attempt to repair this actuator, send it to APV or an APV
approved repair facility. Australian Pipeline Valve and it’s parent company take no
responsibility for damage or injury to people, property or equipment. It is the sole
responsibility of the user to ensure only specially trained actuator repair experts
perform repairs under the supervision of a qualified supervisor.
For low and high temperature service. Special lubricant is required. Please contact
APV for each application. High and low temperature will vary changing the output
torque of the actuator.