ACTUATORS - RP SERIES
Australian Pipeline Valve - Installation, Operation and Maintenance Manual
2
O V E R V I E W
This instruction manual is for rack & pinion pneumatic actuators. The RP Series rack &
pinion pneumatic actuator has been designed, developed and tested incorporating the
latest technology and materials available, with some innovative design features. As a
result of this product research we have obtained a high grade product with the following
characteristics:
• Reliability
• High performance
• Wider product range permitting a more economical sizing
selection.
• Innovative and patented universal drive shaft and multifunction
position indicator
• Full compliance with latest worldwide specifications
• A wide selection of highest levels of corrosion protection
technology
• Aesthetically compact and modern style with no external cavities
to avoid deposit build up.
Product Code
Chamber 50, 100
Acting Way
“DA” double acting (DA)
“SR” Single acting (spring return)
Operating temperature
Normal temperature NT (Slightly) temperature-20°C~+80°C
Low temperature LT temperature -40°C~+80°C
High temperature HT temperature -15°C~+150°C
Operating media:
Dry or lubricated air or inert /non-corrosive gases on condition that
they are compatible with internal actuator parts and lubricant. The
operating media must have a dew point equal to -20°C (-40°F) or at
least 10°C below the ambient temperature. The maximum particle size
must not exceed 30 μm
Supplying Pressure:
For Double Acting and spring Return actuators the maximum supply
pressure is 8 Bar (116PSI). Minimum supply pressure is 2.5 Bar (36PSI)
Operating Temperature:
• Standard product from -20°C (-4°F) to +80°C (+176°F)
• Low temperature LT actuator with VMQ ‘O’ Rings from -40°C (-40°F)
RP
AS 4629