5. Auxiliary Equipment
5.1.
Valve position indication
-
A proximity switch holder for the limit position NC or NO of the valve
shaft can be installed directly on the actutor.
We recommend using our standard types:
Operating distance: 5 mm / Diameter: 11 mm.
Operating voltage: 10 - 30 VDC
Outlet: operating voltage pnp positive switching
Connection: moulded cable 5 m length
Protective type: IP 67
Reference number: 08 - 60 - 011/93; H16223
If the operator decides to use valve position indicators other than
APV type, we cannot take over any guarantee for a faultless
function.
5.2.
Control unit (fig. 5.2.)
Units with feedback switch and solenoid valve for the pneumatic
control of the valve to be installed at the actuator are available in
fieldbus technology.
For the start-up, assembly and disassembly of the different designs,
please refer to the different instruction manuals.
The following different designs are available:
CU4 – Direct Connect
ref.-No.; ID-No.
CU41 – S - Direct Connect
08-45-100/93; H320460
CU4 – AS-interface 62 Slaves
ref.-No.; ID-No.
CU41 – S - AS-i extended
08-45-110/93; H320467
CU4 – AS-interface 31 Slaves
ref.-No.; ID-No.
CU41 – S - AS-i standard
08-45-250/93; H324674
CU3 – Profibus
ref.-No.; ID-No.
CU31 – Profibus
08-45-001/93; H315495
CU3 – DeviceNet
ref.-No.; ID-No.
CU31 – DeviceNet
16-31-240/93; H209422
5.3.
Adapter for control unit
-
For the assembly of the Control Unit on the SWmin 4 valve, two
- adapters are required.
adapter
Designation
ref.-No.; ID-No.
CU4-Smini – adapter complete
000 08-48-613/93; H321989
Designation
ref.-No.; ID-No.
CU3 adapter cpl.
000 08-48-415/93; H209430
Designation
ref.-No.; ID-No.
CU3 adapter SWmini4
000 08-48-355/93; H207570
fig. 5.2.
fig. 5.1.
CU4
control unit
CU3
control unit