12. Service Instructions - Shut-off valve
The item numbers refer to the corresponding spare parts lists
SWmini 41–44, SWEmini 41–44 FS/FH-VSM,
CU RN 01.054.815 / RN 01.054.816
12.1. Dismantling from the line system
1.
Shut off line pressure and discharge lines if possible.
2. Valve design with steam chamber:
-
Shut off steam supply. Separate connection only afterwards.
Attention!
Risk of injury by hot components.
3.
Detach electric connections.
- Proximity switches at the proximity switch holder.
-
Control Unit, see instruction manual.
4. Valve design NC: Control actuator with air.
Do not touch movable parts!
Risk of injury by sudden valve operation.
5.
Remove screws (14) M5x12. Withdraw the insert from the housing .
6.
Shut off compressed air and remove compressed air supply.