CHECK VALVES - SWING, TILTING DISC & PISTON - API594/API6D/BS1868/B16.34
Australian Pipeline Valve - Installation, Operation and Maintenance Manual
3
S A F E T Y I N F O R M A T I O N
The following general safety information should be taken into account in addition to the specific warnings
and cautions specified in this manual. They are recommended precautions that must be understood and
applied during operation and maintenance of the equipment covered in this I.O.M.
To avoid injury, never attempt disassembly while there are pressures either
upstream or downstream. Even when replacing gaskets, caution is necessary to
avoid possible injury. Disassemble with caution in case all pressures are not relieved.
To prevent valve bending, damage, inefficient operation, or early maintenance
problems, support piping on each side of the valve. Warning, certain gases and
fluids could cause damage to human health, the environment or property hence the
necessary safety precautions to prevent risk should be taken.
This manual provides instructions for storing, general servicing, installation and removal of check valves.
APV and it’s resellers refuse any liability for damage to people, property or plant as well as loss of
production and loss of income under any circumstances but especially if caused by: Incorrect installation
or utilisation of the valve or if the valve installed is not fit for intended purpose. It is the sole
responsibility of the user to ensure the valve type and materials are correctly specified.
DURING OPERATION TAKE INTO ACCOUNT THE FOLLOWING WARNINGS:
a- Graphite body gaskets (where applicable) are very brittle, any compacting, twisting or bending should
be avoided.
b- The valve’s internal parts (disc/stem/hinge pin/seats/gaskets/seals, etc.) shall be handled with care
avoiding scratches or surface damage.
c- All tools and equipment for handling the internal parts shall be soft coated, or else take care.
d- Valves can be fitted with gaskets or seals in PTFE, Buna, Viton, etc., hence high temperatures and some
cleaning fluids may damage sealing components.
For all operations make reference to position number on part list of the applicable drawing.