5
AU
Telephone Helpline: 1300225960
Cleaning, Care & Maintenance
• Always turn Off the appliance and disconnect from the power supply before cleaning.
• Allow the appliance to cool before cleaning.
• The inner body of the appliance should be wiped down at the end of each day’s operation. Additional
cleaning may be required depending on frequency of use.
• Warm soapy water is recommended for cleaning. Cleaning agents may cause damage or leave
harmful residues when used for a prolonged period on stainless steel.
• The Apuro dealer or qualified technician should carry out repairs if required.
Troubleshooting
If your Apuro Pie Warmer develops a fault, please check the following table before making a service call.
Fault
Probable Cause
Solution
Appliance not
working
The unit is not switched on
Check the unit is plugged in correctly and
switched on
Plug and lead are damaged
Call Apuro agent or qualified Technician
Power supply
Check power supply
Internal wiring fault
Call Apuro agent or qualified technician
Appliance heats up
but indicator light
does not come on
Indicator light is faulty
Call Apuro agent or qualified technician
Unit not heating up
or heats up slowly
and the indicator
light is On
Incorrect operation
Ensure:
• Thermostat has been set correctly
• Doors are closed
• Thermostat sensor bulb has not been
removed or damaged
Thermostat failure
Call Apuro agent or qualified technician
Element failure
Call Apuro agent or qualified technician
Technical Specifications
Model
Voltage
Power
Current
Dimensions
H x W x D mm
Weight
Approx.
pie
capacity
Heat up
Time
(to 90°C)
Temp.
Range
DC858-A 220-240V,
50Hz
350W
1.5A
435 x 470 x 365
16kg
30
27 min.
30-90°C
DC859-A
650W
2.8A
435 x 745 x 365
23kg
60
28 min.
DC858-A_DC859-A_A5_v1 2020915.indb 5