background image

 

3. Product Overview 

 

 

 

4. Installation 

NOTE: 

Before installation, please inspect the unit. Be sure that nothing inside the package is damaged.   

 

Mounting the unit 

The unit ONLY can be mounted vertically to a wall surface.   
Please follow below steps: 
1. Turn off the unit before mounting. 
2. Select an appropriate mounting location. Use a horizontal line and the 

length of the line must be 80 mm and mark the two ends on the wall. 
(see right chart) 

3. Drill two marks by screws.   
4. Mount the unit by positioning the key-hole slots over the mounting screws. 

 

Connect to Utility and Charge 

Plug in the AC input cord to the wall outlet. The unit will automatically charge the 
connected external battery even though the unit is off.   

 
Connect External Battery 

Step 1- 

Take away the cover of external battery terminal.

 

Step 2

- Following battery polarity guide printed near the battery terminal!   

Place the external battery cable ring terminal over the battery terminal.   

RED cable to the positive terminal (+);   
BLACK cable to the negative terminal (-). 

 
WARNING! 

Please use the appropriate battery cable. Please refer to 

Important Safety Warnings Section 

for the details. 

 

Step 3

- Tight the battery cables with the M5 nuts. Do NOT place anything between the flat part of battery 

terminal and the battery cable ring terminal, or overheating may occur. 

(See Fig. 1) 

Fig. 1 

 
Step 4

- Install a DC Breaker in a positive battery line. The rating of the DC Breaker must be according to the 

inverter's battery current (75 Amp). Keep the DC breaker off.

 (see Fig. 2) 

 
Step 5

- Connect battery cables to the external batteries. Note: For the user operation safety, we strongly 

recommend that you should use tapes to isolate the battery terminals before you start to operate the unit.   

1)

 

Single battery connection (Refer to Fig. 2):

 When using a single battery, its voltage must be equal to 

the Nominal DC Voltage of the unit

 (see below Table 1). 

 

 Power switch

 

 Status indicators (please see the 

Operation section for the details) 

 LCD display 

 

Output receptacles

 

 AC input

 

 

Input circuit breaker

   

 External battery connectors

 

Summary of Contents for Inverex XP Pro 1200

Page 1: ...Inverex Inverter V 1 0 Quick Guide...

Page 2: ...Table of Contents 1 Introduction 1 2 Important Safety Warning SAVE THESE INSTRUCTIONS 1 3 Product Overview 2 4 Installation 2 5 Operation 3 6 Trouble Shooting 8 7 Specifications 8...

Page 3: ...y cable reference according to system requirements CAUTION Do not disassemble the inverter Contact with the qualified service center when service or repair is required WARNING Provide ventilation to o...

Page 4: ...the battery terminal RED cable to the positive terminal BLACK cable to the negative terminal WARNING Please use the appropriate battery cable Please refer to Important Safety Warnings Section for the...

Page 5: ...alled press the power switch to turn on the unit The unit will work automatically in line mode or inverter mode according to input utility power s status When press the power switch again the unit wil...

Page 6: ...Voltage mode 11Vdc pcs 4 bars will flash in turns 11Vdc 11 5Vdc pcs Bottom bar will be on and the other three bars will flash in turns 11 5Vdc 12 5Vdc pcs Bottom two bars will be on and the other two...

Page 7: ...efined If User Defined is selected battery charge voltage and low DC cut off voltage can be set up in program 04 05 and 06 03 Max AC charging current 10A 20A default 04 Bulk charging voltage C V volta...

Page 8: ...age will be fixed to setting value no matter what percentage of load is connected Display Setting The LCD display information will be switched in turns by pressing SCROLL key The selectable informatio...

Page 9: ...utility Line Mode The unit will provide output power from the mains It will also charge the battery at line mode Charging by utility Battery Mode The unit will provide output power from battery Fault...

Page 10: ...the external battery cable and terminal Make sure all the battery connections to the unit are all correct Battery defect Replace the batteries Buzzer beeps continuously and red LED is on Fault code 00...

Reviews: