7.8.3
PULSE Sub-system
The PULSE sub-system controls output transient pulse mode programming.
Command
Description
PULSE:CYCLE:_<nr2>
Sets the repeat time of the pulse. Range is 0 ~ 65535. A 0
setting means infinite loop. Returns OK or FALSE.
PULSE:DEGREE:_<nr2>
Sets the start angle of the pulse in degrees. Range is 0.0 ~
359.9. Returns OK or FALSE.
PULSE:DUTYCYCLE:_<nr2>
Sets the duty cycle of the pulse in percent. Range is 0.0 ~ 100.0.
Returns OK or FALSE.
PULSE:FREQ:_<nr2>
Sets the frequency of the pulse in Hz. Range is 15.00 ~ 1000.00
for Standard models or 15.00 ~ 1200.00 for Enhanced models.
Returns OK or FALSE.
PULSE:PERIOD:_<nr2>
Sets the cycle time of the pulse in msec. Range is 0 ~
9999999.9. Returns OK or FALSE.
PULSE:REMAINTIME?
Queries the remaining time of the pulse execution in seconds.
Range is 0.0 ~ 6553434465.
PULSE:START:_<nr2>
Sets when to run the pulse waveform in msecs. Range is 0.0 ~
25.0. Returns OK or FALSE.
PULSE:TRIGER
>>> PULSE:TRIGGER <<<
Starts execution of the pulse transient. Returns OK.
Note:
Remote firmware revision
V100R002C21
of lower will not accept
correct spelling of TRIGGER key word. Use TRIGER as shown instead.
PULSE:STOP
Abort execution of the pulse transient. Returns OK.
PULSE:VAC:_<nr2>
Sets the pulse AC voltage in volts. Range is 0.0 ~ 300.0. Returns
OK or FALSE.
PULSE:VDC:_<nr2>
Sets the pulse DC voltage in volts. Range is -424.2 ~ 424.2.
Returns OK or FALSE.
PULSE:WAVEFORM:_<nr2>
Selects waveform group A (0) or B (1) for the pulse. Returns OK
or FALSE.
Table 7-11: PULSE Sub-system Commands