background image

 

10 

 

RMC

 

 

Door opener: 

Rack Multi Control has a built in door opening function. In conjunction 
with an electronic locking mechanism, the door can be controlled by a 
4 to 8 digit code. The opening mechanism has an adjustable response 
time of 1 to 60 seconds. The function can also be activated by a virtual 

"open door

" button on the PC screen.  

 
 
 

Alarm reset:

 

 

When an alarm is raised, the channel indicator lamp starts blinking in 
red, both on the RMC and on the main web page. By pressing any of 
the front panel buttons or by clicking this button 

“Alarm reset”

 on the 

PC screen, the alarm will be acknowledged. 

 
 
 
 
 

Settings:

 

The button 

“Settings”

 opens the pages for configuration. 

 
 
 
 

Support:

 

The 

“help”

  button  links  to  the  support  web  site,  where  the  latest 

documentation is available. 

 
 
 
 
 

Outputs: 

This  buttons  can  be  freely  named  and  can  be  used  to  manually 
operate  the  potential-free  outputs  or  show  their  status  depending  on 
the configuration. 
 
 
Important: 
This function is disabled if the potential-free outputs are configured for 
a different function. 

 
 
 
 

RMC

Summary of Contents for 901-0101

Page 1: ...APS Rack Multi Control RMC Manual...

Page 2: ...Operation 7 Factory settings 8 Network installation 8 Graphic User Interface 9 Set time and date 9 Open the door 10 Alarm reset 10 Settings 10 Support 10 Power outputs 10 Settings 11 Alarm Status cha...

Page 3: ...19 Rack and requires one rack unit space The RMC has an internal power unit and connects to a 230 VAC outlet It is recommended to have the RMC connected to an UPS Wiring diagram 1 2 3 4 5 6 7 8 9 10...

Page 4: ...s condition as ON Choose normally closed when this corresponds to the standard condition Analogue Inputs The 4 analogue inputs are connected as follows Input 1 2 and 3 are for temperature sensors The...

Page 5: ...to the code lock interface Important If the Code Lock Unit for Emka 2100 accessory is in use do not connect pins 29 and 30 since the Emka systems has its own power supply Power Relays The 3 power rela...

Page 6: ...4 RS232 Front Interface 2 Display 5 Link Active LED 3 Navigation buttons Back side 1 Modem Interface RS232 5 Analogue Inputs 2 Keypad Interface Emka 2100 6 Alarm and Door Output 3 Ethernet Port 7 Out...

Page 7: ...s displayed When the sensor is installed in the wrong manner the RMC will display Temp sensor error If there is only one temperature sensor connected it must be installed on analogue Input 1 The 8 dig...

Page 8: ...is necessary to set an IP address and Subnet mask on the PC used for configuration The IP address on the RMC is set by using the navigation buttons on the device itself Use the button Down and scroll...

Page 9: ...vent In case of a reboot the list of events is erased and RMC Reboot appears Set time and date In consideration of the environment and to avoid unnecessary maintenance the RMC has a calendar clock wit...

Page 10: ...ng in red both on the RMC and on the main web page By pressing any of the front panel buttons or by clicking this button Alarm reset on the PC screen the alarm will be acknowledged Settings The button...

Page 11: ...or lamp flashing even if the alarm condition no longer remains This makes it possible to observe intermittent error conditions If Alarm auto ack is selected the channel is automatically reset when the...

Page 12: ...ol by temperature sensor 2 or manual control on off for the basic setting of the relay after a reboot Output 3 Select Heating if temp 1 low for temperature control by temperature sensor 1 Cooling if T...

Page 13: ...edge Passwords Lock codes These controls access to all web pages The factory settings shown should be changed The Lock code temporary controls the code to be entered on the keypad to open the door The...

Page 14: ...rn to the main page GSM Modem In order for the RMC to send notifications by text messages a GSM modem needs to be connected to the RS232 Interface GSM modem is an optional accessory The RMC confirms t...

Page 15: ...Status for the three potential free outputs Can also be set on or off by the NMS rmcTrapMessage When an alarm trap is sent this object holds the alarm text string which is appended to the trap In the...

Page 16: ...0101 RMC Rack Multi Control 832 700 902 GSM Modem xmodus inkl 832 700 910 DIN Assembly clip to Modem 901 0120 Temperature Sensor RMC 0 2 m 901 0121 Temperature Sensor RMC 3 0 m 901 0103 Smoke Detecto...

Reviews: