4. Wiring diagram
Terminal board for connecting
mains supply circuit and motor
Terminal board for connecting
controls and safety devices
fig.4.1
fig.4.2
Connect Phase and Neutral Wire of the mains supply as shown in
the picture.
Controls and available inputs with optional cable:
Local Open
: connect the NO contact of a device such as a
pushbutton used to send an open pulse to the automation between
grey cable and pink cable.
Local Close
: connect the NO contact of a device such as a
pushbutton used to transmit a close pulse to the automation between
grey cable and yellow cable.
Centralized Open
: connect the NO contact of a device used to
transmit an open pulse to more automation systems between grey
cable and brown cable (see farther).
Centralized Close
: connect the NO contact of a device used to
transmit a close pulse to more automation systems between grey
cable and green cable (see farther).
Stop
: connect the NC contact of a device such as a red mushroom-
head pushbutton with mechanical lock used to stop the automation in
an emergency between grey cable and white cable.
Safety
: connect the NC contact of a device such as a photocell
between terminals 10 and 11. In stand-by mode, this device stops the
automation, while, during the closing phase, it reverses the motion
and prevents entrapment risks.
Open jumper JP5 to connect a Stop device; open jumper JP6 to
connect a safety device.
The appliance is not equipped with output for powering
accessories or safety devices. If such devices have to be used,
they must be powered through an external source.
!