on/off
DIAGNOSIS INSTRUMENT:
ACTIVATIONS
Fan
•
The fan relay (No. 36 in the wiring dia-
gram, placed in the headstock niche,
left side; CHECK, however, the identi-
fication of the relay with the colour of
the cables) is energised for 10 sec-
onds. The continuity of the wiring is
necessary for correct activation: no er-
ror indications are displayed in case of
lack of activation
CAUTION
BEFORE CARRYING OUT ANY TROUBLESHOOTING,
CAREFULLY READ THE GENERAL TROUBLESHOOTING
CONCEPTS FOR ELECTRICAL DEVICES AT THE BEGIN-
NING OF THE CHECK AND CONTROL SECTION IN THE
ELECTRICAL SYSTEM CHAPTER.
DIAGNOSIS INSTRUMENT: ELECTRICAL ERRORS
Cooling fan relay P0480
•
short circuit to positive/ short circuit to negative / open circuit
Error cause
•
If shorted to positive: excessive voltage has been detected at PIN 61 of the VEHICLE con-
nector. If shorted to negative: no voltage has been detected. If the circuit is open: 5V voltage
has been detected. Error recognition carries out only when the fan relay is activated.
Troubleshooting
•
If shorted to positive: check the relay electrical specifications are correct by disconnecting
it from the cable harness. If not OK, replace the relay; if OK, restore the cable harness (brown
cable)
•
If shorted to negative: check the relay electrical specifications are correct by disconnecting
it from the cable harness. If not OK, replace the relay; if OK, restore the cable harness (brown
cable)
•
If the circuit is open: check the relay electrical characteristics are correct by disconnecting
it from the cable harness; if it is not OK, replace the relay, if it is OK, check relay connector,
engine-vehicle cable harness connector and VEHICLE connector of the Marelli control unit:
if not OK, restore; if OK, check continuity of cable harness (brown cable)
Electrical system
RSV4 Factory a-PRC
ELE SYS - 220
Summary of Contents for RSV4 Factory a-PRC 2009
Page 1: ...SERVICE STATION MANUAL 898952 RSV4 Factory a PRC ...
Page 4: ......
Page 6: ...INDEX OF TOPICS CHARACTERISTICS CHAR ...
Page 52: ...INDEX OF TOPICS SPECIAL TOOLS S TOOLS ...
Page 60: ...INDEX OF TOPICS MAINTENANCE MAIN ...
Page 84: ...INDEX OF TOPICS TROUBLESHOOTING TROUBL ...
Page 94: ... 7 REPLACE THE STARTER BUTTON COMPONENT END Troubleshooting RSV4 Factory a PRC TROUBL 94 ...
Page 95: ...INDEX OF TOPICS ELECTRICAL SYSTEM ELE SYS ...
Page 249: ...INDEX OF TOPICS ENGINE FROM VEHICLE ENG VE ...
Page 270: ...INDEX OF TOPICS ENGINE ENG ...
Page 387: ...INDEX OF TOPICS POWER SUPPLY P SUPP ...
Page 398: ...INDEX OF TOPICS SUSPENSIONS SUSP ...
Page 436: ...INDEX OF TOPICS CHASSIS CHAS ...
Page 460: ...INDEX OF TOPICS BRAKING SYSTEM BRAK SYS ...
Page 472: ...INDEX OF TOPICS COOLING SYSTEM COOL SYS ...
Page 483: ...INDEX OF TOPICS BODYWORK BODYW ...